    Retrofitting of Structural Steel Channel Sections Using Cold-Formed Steel Encasing Channels

    Source: Journal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 004
    Author:
    Selvaraj Sivaganesh;Madhavan Mahendrakumar
    DOI: 10.1061/(ASCE)CF.1943-5509.0001187
    Publisher: American Society of Civil Engineers
    Abstract: A four-point bending test was carried out to examine the feasibility of using cold-formed steel (CFS) channel for retrofitting of open hot rolled steel (HRS) channels. The retrofitting technique using CFS section transforms the open-channel HRS section to a closed composite (HRS–CFS) section, thereby increasing its torsional rigidity to inhibit failure due to lateral–torsional buckling (LTB). The integrity of the HRS–CFS section was ensured by adequate spot welding of the CFS section to the HRS at regular intervals along the length of the member. This technique has the advantage of accumulating minimum residual stress (spot welding) in addition to reduced manpower required for section fabrication. The test results, in general, indicate that this technique can significantly increase the load-carrying capacity (up to 6% compared to the control specimen) without deformation when local buckling of the CFS sections can be prevented by providing adequate thickness and smaller weld intervals. In addition, the test results indicate that the current specification for both HRS and CFS requires modification to adopt the same for a built-up section made of both HRS and CFS. Based on the test results, a new interconnection spacing limitation to avoid the local buckling of the CFS channel is suggested.
    • Download: (6.466Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Retrofitting of Structural Steel Channel Sections Using Cold-Formed Steel Encasing Channels

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4248507
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorSelvaraj Sivaganesh;Madhavan Mahendrakumar
    date accessioned2019-02-26T07:39:05Z
    date available2019-02-26T07:39:05Z
    date issued2018
    identifier other%28ASCE%29CF.1943-5509.0001187.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248507
    description abstractA four-point bending test was carried out to examine the feasibility of using cold-formed steel (CFS) channel for retrofitting of open hot rolled steel (HRS) channels. The retrofitting technique using CFS section transforms the open-channel HRS section to a closed composite (HRS–CFS) section, thereby increasing its torsional rigidity to inhibit failure due to lateral–torsional buckling (LTB). The integrity of the HRS–CFS section was ensured by adequate spot welding of the CFS section to the HRS at regular intervals along the length of the member. This technique has the advantage of accumulating minimum residual stress (spot welding) in addition to reduced manpower required for section fabrication. The test results, in general, indicate that this technique can significantly increase the load-carrying capacity (up to 6% compared to the control specimen) without deformation when local buckling of the CFS sections can be prevented by providing adequate thickness and smaller weld intervals. In addition, the test results indicate that the current specification for both HRS and CFS requires modification to adopt the same for a built-up section made of both HRS and CFS. Based on the test results, a new interconnection spacing limitation to avoid the local buckling of the CFS channel is suggested.
    publisherAmerican Society of Civil Engineers
    titleRetrofitting of Structural Steel Channel Sections Using Cold-Formed Steel Encasing Channels
    typeJournal Paper
    journal volume32
    journal issue4
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001187
    page4018049
    treeJournal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 004
    contenttypeFulltext