    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Reliability of Symmetric and Asymmetric Structures Mounted on TCFP Base Isolators Subjected to Near-Field Earthquakes

    Source: Journal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 004
    Author:
    Tajammolian Hamed;Khoshnoudian Faramarz
    DOI: 10.1061/(ASCE)CF.1943-5509.0001182
    Publisher: American Society of Civil Engineers
    Abstract: The reliability of structures isolated with Triple Concave Friction Pendulum (TCFP) bearings subjected to near-field earthquakes is investigated. An extensive study is conducted to reveal the effect of superstructure mass eccentricity on the probability of failure (Pf) as well as the reliability index (β) of the structure supported on TCFPs with different properties. Results of different investigations show that friction coefficient of frictional isolators depends on several parameters; therefore, it should be assumed as a random variable. In order to consider the uncertainty of earthquake records a group of 45 sets of near-fault ground motion is selected and its amplitude is scaled with a random variable calculated based upon seismic hazard curve in a specific location. The seismic performance of structures is studied through four damage states (DSs) namely slight, moderate, extensive, and complete structural damages. Two essential engineering demand parameters (EDP) (i.e., interstory drift and acceleration) are assumed as performance functions in reliability-based investigation. The First Order Reliability Method (FORM) analysis performed by Risk Tools (RT) program demonstrated that complete structural DS has lower Pf and larger β compared to slight or moderate DS. Additionally, 3% of mass eccentricity has reduced the β to 23% in a six-story superstructure mounted on a 4-second-period isolator.
    • Download: (2.047Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Reliability of Symmetric and Asymmetric Structures Mounted on TCFP Base Isolators Subjected to Near-Field Earthquakes

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4248502
    Collections
    • Journal of Performance of Constructed Facilities

    Show full item record

    contributor authorTajammolian Hamed;Khoshnoudian Faramarz
    date accessioned2019-02-26T07:39:01Z
    date available2019-02-26T07:39:01Z
    date issued2018
    identifier other%28ASCE%29CF.1943-5509.0001182.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248502
    description abstractThe reliability of structures isolated with Triple Concave Friction Pendulum (TCFP) bearings subjected to near-field earthquakes is investigated. An extensive study is conducted to reveal the effect of superstructure mass eccentricity on the probability of failure (Pf) as well as the reliability index (β) of the structure supported on TCFPs with different properties. Results of different investigations show that friction coefficient of frictional isolators depends on several parameters; therefore, it should be assumed as a random variable. In order to consider the uncertainty of earthquake records a group of 45 sets of near-fault ground motion is selected and its amplitude is scaled with a random variable calculated based upon seismic hazard curve in a specific location. The seismic performance of structures is studied through four damage states (DSs) namely slight, moderate, extensive, and complete structural damages. Two essential engineering demand parameters (EDP) (i.e., interstory drift and acceleration) are assumed as performance functions in reliability-based investigation. The First Order Reliability Method (FORM) analysis performed by Risk Tools (RT) program demonstrated that complete structural DS has lower Pf and larger β compared to slight or moderate DS. Additionally, 3% of mass eccentricity has reduced the β to 23% in a six-story superstructure mounted on a 4-second-period isolator.
    publisherAmerican Society of Civil Engineers
    titleReliability of Symmetric and Asymmetric Structures Mounted on TCFP Base Isolators Subjected to Near-Field Earthquakes
    typeJournal Paper
    journal volume32
    journal issue4
    journal titleJournal of Performance of Constructed Facilities
    identifier doi10.1061/(ASCE)CF.1943-5509.0001182
    page4018042
    treeJournal of Performance of Constructed Facilities:;2018:;Volume ( 032 ):;issue: 004
    contenttypeFulltext