    Steel Coupling Beams with a Replaceable Fuse

    Source: Journal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 002
    Author:
    Shahrooz Bahram M.;Fortney Patrick J.;Harries Kent A.
    DOI: 10.1061/(ASCE)ST.1943-541X.0001939
    Publisher: American Society of Civil Engineers
    Abstract: Steel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 2-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.
    • Download: (1.714Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Steel Coupling Beams with a Replaceable Fuse

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4248419
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorShahrooz Bahram M.;Fortney Patrick J.;Harries Kent A.
    date accessioned2019-02-26T07:38:12Z
    date available2019-02-26T07:38:12Z
    date issued2018
    identifier other%28ASCE%29ST.1943-541X.0001939.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248419
    description abstractSteel coupling beams have emerged as a viable alternative to conventionally and diagonally reinforced concrete coupling beams because of their superior energy-dissipation characteristics, smaller member depth, and ease of construction, to name but a few advantages. Conventional steel coupling beams are designed to yield under design-level ground motions; hence, postevent repair requires replacement of the entire beam that is embedded into wall piers and interfaced with a significant amount of wall pier reinforcement. Such a repair will be costly, intrusive, and very likely impractical. A new system involving a replaceable midspan fuse located in the coupling beam was developed. In this system, the fuse acts as the primary energy-dissipating component, while the remainder of the beam span and its embedments into the wall piers remain elastic when the building is subjected to design-level ground motions. Hence, it is only necessary to replace the accessible damaged fuses since the rest of the beam and wall piers remain undamaged. This paper presents a design methodology for using steel coupling beams that have a replaceable fuse. Laboratory test data were found to validate the methodology. A 2-story prototype building was designed according to the proposed methodology and results from nonlinear static and dynamic analyses indicate that the building performed according to the objectives of the presented design methodology. That is, (1) the midspan fuses are the primary energy-dissipating components; (2) the fuses develop their capacity before the embedded beams reach their expected shear or elastic flexural capacities; (3) the wall piers experience little or no damage under design ground motions; (4) the wall piers maintain their integrity for maximum credible ground motions; and (5) residual deformations are small, permitting new fuses to be installed following design-level ground motions.
    publisherAmerican Society of Civil Engineers
    titleSteel Coupling Beams with a Replaceable Fuse
    typeJournal Paper
    journal volume144
    journal issue2
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001939
    page4017210
    treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian