    Seismic-Response Analysis of RC C-Shaped Core Walls Subjected to Combined Flexure, Shear, and Torsion

    Source: Journal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 010
    Author:
    Arabzadeh Hamid;Galal Khaled
    DOI: 10.1061/(ASCE)ST.1943-541X.0002181
    Publisher: American Society of Civil Engineers
    Abstract: Although dynamic torsional responses are often regarded as secondary effects in the seismic design of symmetric-plan buildings, torsional effects arising from plan asymmetry can be substantial in some cases. In RC wall buildings, a combination of flexural, shear, and torsion dictates the type of failure, which needs to be addressed in the design of RC walls. This study investigates two aspects of building structures with C-shaped RC walls: (1) evaluation of seismic force demand at different levels of torsional sensitivity, and (2) effectiveness of using the dual plastic hinge method in controlling the seismic shear force demand. A macroscale modeling approach using the wide column analogy captures the inelastic response of C-shaped RC wall buildings, including torsional effects. The numerical model of the wall is validated against available experimental data. Nonlinear time history analyses of typical multistory buildings located in eastern North America (8-, 12-, and 16-story) are performed. Four different levels of torsional sensitivity (B=1.3, 1.7, 2., and 2.5) are considered for each building configuration. Although the studied range of torsional sensitivity has no substantial effect on the bending moment envelope of the building, it significantly increases the story shear force demand during an earthquake. The shear force envelopes in torsionally sensitive buildings (B>1.7) exceed the capacity design envelope predicted by the response spectrum analysis of a large number of selected ground motions. The dual plastic hinge design method recently proposed by other researchers is adopted and is found to be an efficient method, resulting in lower shear force demand along the height of the structure, especially when high torsional flexibility is expected.
    • Download: (1.183Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Seismic-Response Analysis of RC C-Shaped Core Walls Subjected to Combined Flexure, Shear, and Torsion

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4248063
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorArabzadeh Hamid;Galal Khaled
    date accessioned2019-02-26T07:35:04Z
    date available2019-02-26T07:35:04Z
    date issued2018
    identifier other%28ASCE%29ST.1943-541X.0002181.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4248063
    description abstractAlthough dynamic torsional responses are often regarded as secondary effects in the seismic design of symmetric-plan buildings, torsional effects arising from plan asymmetry can be substantial in some cases. In RC wall buildings, a combination of flexural, shear, and torsion dictates the type of failure, which needs to be addressed in the design of RC walls. This study investigates two aspects of building structures with C-shaped RC walls: (1) evaluation of seismic force demand at different levels of torsional sensitivity, and (2) effectiveness of using the dual plastic hinge method in controlling the seismic shear force demand. A macroscale modeling approach using the wide column analogy captures the inelastic response of C-shaped RC wall buildings, including torsional effects. The numerical model of the wall is validated against available experimental data. Nonlinear time history analyses of typical multistory buildings located in eastern North America (8-, 12-, and 16-story) are performed. Four different levels of torsional sensitivity (B=1.3, 1.7, 2., and 2.5) are considered for each building configuration. Although the studied range of torsional sensitivity has no substantial effect on the bending moment envelope of the building, it significantly increases the story shear force demand during an earthquake. The shear force envelopes in torsionally sensitive buildings (B>1.7) exceed the capacity design envelope predicted by the response spectrum analysis of a large number of selected ground motions. The dual plastic hinge design method recently proposed by other researchers is adopted and is found to be an efficient method, resulting in lower shear force demand along the height of the structure, especially when high torsional flexibility is expected.
    publisherAmerican Society of Civil Engineers
    titleSeismic-Response Analysis of RC C-Shaped Core Walls Subjected to Combined Flexure, Shear, and Torsion
    typeJournal Paper
    journal volume144
    journal issue10
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0002181
    page4018165
    treeJournal of Structural Engineering:;2018:;Volume ( 144 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian