Strength Evaluation of Concrete Columns with Cross-Sectional HolesSource: Practice Periodical on Structural Design and Construction:;2018:;Volume ( 023 ):;issue: 004Author:Kassim Muayad M.;Ahmad Shahin A.
DOI: 10.1061/(ASCE)SC.1943-5576.0000391Publisher: American Society of Civil Engineers
Abstract: Today, concealing a longitudinal circular rainwater pipe in the center of a column cross section is common practice in the construction of skeleton RC frames. This research studies the strength reduction caused in short braced columns and the effect of factors that will increase or reduce the strength change. Sixteen columns (1 × 1 × 5 mm) were tested to investigate the effects of the hole:cross section ratio (i.e., the ratio of the hole to the cross section), concrete compressive strength, main reinforcement ratio, and ties spacing on the axial load capacity of the columns. The longitudinal and lateral deformations of the columns were measured to determine the first crack appearance and elastic work of the columns. The test results show that changing the hole diameter within the cross-sectional area has a major significant effect on load carrying capacity, in which a 5 and 1.8% reduction in the cross-sectional area caused a decrease of 2 and 1% in bearing strength capacity, respectively. However, increasing the concrete compressive strength and the reinforcement ratio does not show a considerable effect, whereas the spacing of the ties has a minor effect on the results.
|
Show full item record
| contributor author | Kassim Muayad M.;Ahmad Shahin A. | |
| date accessioned | 2019-02-26T07:33:49Z | |
| date available | 2019-02-26T07:33:49Z | |
| date issued | 2018 | |
| identifier other | %28ASCE%29SC.1943-5576.0000391.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4247918 | |
| description abstract | Today, concealing a longitudinal circular rainwater pipe in the center of a column cross section is common practice in the construction of skeleton RC frames. This research studies the strength reduction caused in short braced columns and the effect of factors that will increase or reduce the strength change. Sixteen columns (1 × 1 × 5 mm) were tested to investigate the effects of the hole:cross section ratio (i.e., the ratio of the hole to the cross section), concrete compressive strength, main reinforcement ratio, and ties spacing on the axial load capacity of the columns. The longitudinal and lateral deformations of the columns were measured to determine the first crack appearance and elastic work of the columns. The test results show that changing the hole diameter within the cross-sectional area has a major significant effect on load carrying capacity, in which a 5 and 1.8% reduction in the cross-sectional area caused a decrease of 2 and 1% in bearing strength capacity, respectively. However, increasing the concrete compressive strength and the reinforcement ratio does not show a considerable effect, whereas the spacing of the ties has a minor effect on the results. | |
| publisher | American Society of Civil Engineers | |
| title | Strength Evaluation of Concrete Columns with Cross-Sectional Holes | |
| type | Journal Paper | |
| journal volume | 23 | |
| journal issue | 4 | |
| journal title | Practice Periodical on Structural Design and Construction | |
| identifier doi | 10.1061/(ASCE)SC.1943-5576.0000391 | |
| page | 4018027 | |
| tree | Practice Periodical on Structural Design and Construction:;2018:;Volume ( 023 ):;issue: 004 | |