YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Structural Design and Construction Practice
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Strength Evaluation of Concrete Columns with Cross-Sectional Holes

    Source: Practice Periodical on Structural Design and Construction:;2018:;Volume ( 023 ):;issue: 004
    Author:
    Kassim Muayad M.;Ahmad Shahin A.
    DOI: 10.1061/(ASCE)SC.1943-5576.0000391
    Publisher: American Society of Civil Engineers
    Abstract: Today, concealing a longitudinal circular rainwater pipe in the center of a column cross section is common practice in the construction of skeleton RC frames. This research studies the strength reduction caused in short braced columns and the effect of factors that will increase or reduce the strength change. Sixteen columns (1 × 1 × 5 mm) were tested to investigate the effects of the hole:cross section ratio (i.e., the ratio of the hole to the cross section), concrete compressive strength, main reinforcement ratio, and ties spacing on the axial load capacity of the columns. The longitudinal and lateral deformations of the columns were measured to determine the first crack appearance and elastic work of the columns. The test results show that changing the hole diameter within the cross-sectional area has a major significant effect on load carrying capacity, in which a 5 and 1.8% reduction in the cross-sectional area caused a decrease of 2 and 1% in bearing strength capacity, respectively. However, increasing the concrete compressive strength and the reinforcement ratio does not show a considerable effect, whereas the spacing of the ties has a minor effect on the results.
    • Download: (1.414Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Strength Evaluation of Concrete Columns with Cross-Sectional Holes

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4247918
    Collections
    • Journal of Structural Design and Construction Practice

    Show full item record

    contributor authorKassim Muayad M.;Ahmad Shahin A.
    date accessioned2019-02-26T07:33:49Z
    date available2019-02-26T07:33:49Z
    date issued2018
    identifier other%28ASCE%29SC.1943-5576.0000391.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4247918
    description abstractToday, concealing a longitudinal circular rainwater pipe in the center of a column cross section is common practice in the construction of skeleton RC frames. This research studies the strength reduction caused in short braced columns and the effect of factors that will increase or reduce the strength change. Sixteen columns (1 × 1 × 5 mm) were tested to investigate the effects of the hole:cross section ratio (i.e., the ratio of the hole to the cross section), concrete compressive strength, main reinforcement ratio, and ties spacing on the axial load capacity of the columns. The longitudinal and lateral deformations of the columns were measured to determine the first crack appearance and elastic work of the columns. The test results show that changing the hole diameter within the cross-sectional area has a major significant effect on load carrying capacity, in which a 5 and 1.8% reduction in the cross-sectional area caused a decrease of 2 and 1% in bearing strength capacity, respectively. However, increasing the concrete compressive strength and the reinforcement ratio does not show a considerable effect, whereas the spacing of the ties has a minor effect on the results.
    publisherAmerican Society of Civil Engineers
    titleStrength Evaluation of Concrete Columns with Cross-Sectional Holes
    typeJournal Paper
    journal volume23
    journal issue4
    journal titlePractice Periodical on Structural Design and Construction
    identifier doi10.1061/(ASCE)SC.1943-5576.0000391
    page4018027
    treePractice Periodical on Structural Design and Construction:;2018:;Volume ( 023 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian