Parametric Study on Seismic Control Design of a New Type of SMA Damper Installed in a Frame-Type Bridge PierSource: Journal of Aerospace Engineering:;2018:;Volume ( 031 ):;issue: 002Author:Li Ran;Ge Hanbin;Shu Ganping
DOI: 10.1061/(ASCE)AS.1943-5525.0000809Publisher: American Society of Civil Engineers
Abstract: This paper focuses on the seismic control design of a new type of shape memory alloy (SMA) damper named double X-typed SMA (DX-SMA) damper. It is installed in a frame-typed bridge pier. A parametric study based on time-history analyses is carried out to investigate the influence of the strength ratio and the span ratio. The amplification effect of the DX-SMA damper is tested by a low cyclic loading process. The performance of the structural safety and the self-centering device postearthquake are evaluated by analyzing the residual top displacement and the maximum top displacement of the frame pier. Lastly, the energy dissipation of the SMA damper is investigated. Design recommendations are suggested following the results of the parametric study.
|
Collections
Show full item record
| contributor author | Li Ran;Ge Hanbin;Shu Ganping | |
| date accessioned | 2019-02-26T07:32:01Z | |
| date available | 2019-02-26T07:32:01Z | |
| date issued | 2018 | |
| identifier other | %28ASCE%29AS.1943-5525.0000809.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4247661 | |
| description abstract | This paper focuses on the seismic control design of a new type of shape memory alloy (SMA) damper named double X-typed SMA (DX-SMA) damper. It is installed in a frame-typed bridge pier. A parametric study based on time-history analyses is carried out to investigate the influence of the strength ratio and the span ratio. The amplification effect of the DX-SMA damper is tested by a low cyclic loading process. The performance of the structural safety and the self-centering device postearthquake are evaluated by analyzing the residual top displacement and the maximum top displacement of the frame pier. Lastly, the energy dissipation of the SMA damper is investigated. Design recommendations are suggested following the results of the parametric study. | |
| publisher | American Society of Civil Engineers | |
| title | Parametric Study on Seismic Control Design of a New Type of SMA Damper Installed in a Frame-Type Bridge Pier | |
| type | Journal Paper | |
| journal volume | 31 | |
| journal issue | 2 | |
| journal title | Journal of Aerospace Engineering | |
| identifier doi | 10.1061/(ASCE)AS.1943-5525.0000809 | |
| page | 4017100 | |
| tree | Journal of Aerospace Engineering:;2018:;Volume ( 031 ):;issue: 002 | |
| contenttype | Fulltext |