    Archive

    New Shear Connector Design for Insulated Concrete Sandwich Panels Using Basalt Fiber-Reinforced Polymer Bars

    Source: Journal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004
    Author:
    Douglas G. Tomlinson
    ,
    Nathan Teixeira
    ,
    Amir Fam
    DOI: 10.1061/(ASCE)CC.1943-5614.0000662
    Publisher: American Society of Civil Engineers
    Abstract: In this study, 38 push-through tests were performed on a precast concrete insulated sandwich panel design using combined angled and horizontal connectors. Basalt fiber-reinforced polymer (BFRP) and steel connectors were tested and compared. The key parameters were various inclination angles and diameters of connectors; orientation of the diagonal connector relative to loading (i.e., tested in tension or compression); and panels with or without an active foam-to-concrete bond. Steel connectors failed by yielding in tension and inelastic buckling in compression. Larger-diameter BFRP connectors usually pulled out under tension and crushed in compression. Smaller-diameter BFRP connectors ruptured in tension and buckled in compression. Strength and stiffness increased with the connector angle and diameter. The insulation foam bond was found to contribute similarly regardless of connector material. An independent theoretical model accounting for material, bond, and stability failure modes, as well as geometric distortion attributable to relative slip, was developed. It provided an average test-to-predicted value of 1.15 with a standard deviation of 0.25 for the strength of the shear connection system.
    • Download: (6.064Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      New Shear Connector Design for Insulated Concrete Sandwich Panels Using Basalt Fiber-Reinforced Polymer Bars

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4245348
    Collections
    • Journal of Composites for Construction

    Show full item record

    contributor authorDouglas G. Tomlinson
    contributor authorNathan Teixeira
    contributor authorAmir Fam
    date accessioned2017-12-30T13:04:36Z
    date available2017-12-30T13:04:36Z
    date issued2016
    identifier other%28ASCE%29CC.1943-5614.0000662.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245348
    description abstractIn this study, 38 push-through tests were performed on a precast concrete insulated sandwich panel design using combined angled and horizontal connectors. Basalt fiber-reinforced polymer (BFRP) and steel connectors were tested and compared. The key parameters were various inclination angles and diameters of connectors; orientation of the diagonal connector relative to loading (i.e., tested in tension or compression); and panels with or without an active foam-to-concrete bond. Steel connectors failed by yielding in tension and inelastic buckling in compression. Larger-diameter BFRP connectors usually pulled out under tension and crushed in compression. Smaller-diameter BFRP connectors ruptured in tension and buckled in compression. Strength and stiffness increased with the connector angle and diameter. The insulation foam bond was found to contribute similarly regardless of connector material. An independent theoretical model accounting for material, bond, and stability failure modes, as well as geometric distortion attributable to relative slip, was developed. It provided an average test-to-predicted value of 1.15 with a standard deviation of 0.25 for the strength of the shear connection system.
    publisherAmerican Society of Civil Engineers
    titleNew Shear Connector Design for Insulated Concrete Sandwich Panels Using Basalt Fiber-Reinforced Polymer Bars
    typeJournal Paper
    journal volume20
    journal issue4
    journal titleJournal of Composites for Construction
    identifier doi10.1061/(ASCE)CC.1943-5614.0000662
    page04016003
    treeJournal of Composites for Construction:;2016:;Volume ( 020 ):;issue: 004
    contenttypeFulltext