YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • International Journal of Geomechanics
    • View Item
    •   YE&T Library
    • ASCE
    • International Journal of Geomechanics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental and Numerical Studies of Circular Footing Resting on Confined Granular Subgrade Adjacent to Slope

    Source: International Journal of Geomechanics:;2016:;Volume ( 016 ):;issue: 001
    Author:
    W. R. Azzam
    ,
    A. Z. ElWakil
    DOI: 10.1061/(ASCE)GM.1943-5622.0000500
    Publisher: American Society of Civil Engineers
    Abstract: Many situations exist where foundations must be constructed on or near slopes. As a result, the foundation’s bearing capacity is reduced, and the slope might collapse. This paper presents the results of laboratory and numerical model tests on the influence of soil confinement on the behavior of a model footing adjacent to slopes. Confining cylinders with different heights, each set back some distance from the slope crest, were adopted. The ultimate bearing capacity of a circular footing supported on a confined sand bed adjacent to a slope was studied. The studied parameters include the cell-embedment depth, slope angle, and subgrade density. The results indicate that the bearing load capacities of circular footings at any edge distance from the slope crest can be appreciably increased by soil confinement. The slope effect on the ultimate bearing capacity can be neglected when the cell-footing system is placed at setback distance with cell-embedment depth around two times the cell diameter. When the cell-footing system is placed directly on a steep slope crest, the improvement in the bearing capacity reached 4, 2.2, and 1.9 times the footing with subgrade relative densities of 80, 55, and 35%, respectively. The numerical analysis helped to explain the deformation behavior of cell-footing soil systems adjacent to a slope. It provides a realistic failure mechanism of the new system and illustrates how the cell can protect the slope from collapse by decreasing slope deformation.
    • Download: (1.394Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental and Numerical Studies of Circular Footing Resting on Confined Granular Subgrade Adjacent to Slope

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4245314
    Collections
    • International Journal of Geomechanics

    Show full item record

    contributor authorW. R. Azzam
    contributor authorA. Z. ElWakil
    date accessioned2017-12-30T13:04:22Z
    date available2017-12-30T13:04:22Z
    date issued2016
    identifier other%28ASCE%29GM.1943-5622.0000500.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4245314
    description abstractMany situations exist where foundations must be constructed on or near slopes. As a result, the foundation’s bearing capacity is reduced, and the slope might collapse. This paper presents the results of laboratory and numerical model tests on the influence of soil confinement on the behavior of a model footing adjacent to slopes. Confining cylinders with different heights, each set back some distance from the slope crest, were adopted. The ultimate bearing capacity of a circular footing supported on a confined sand bed adjacent to a slope was studied. The studied parameters include the cell-embedment depth, slope angle, and subgrade density. The results indicate that the bearing load capacities of circular footings at any edge distance from the slope crest can be appreciably increased by soil confinement. The slope effect on the ultimate bearing capacity can be neglected when the cell-footing system is placed at setback distance with cell-embedment depth around two times the cell diameter. When the cell-footing system is placed directly on a steep slope crest, the improvement in the bearing capacity reached 4, 2.2, and 1.9 times the footing with subgrade relative densities of 80, 55, and 35%, respectively. The numerical analysis helped to explain the deformation behavior of cell-footing soil systems adjacent to a slope. It provides a realistic failure mechanism of the new system and illustrates how the cell can protect the slope from collapse by decreasing slope deformation.
    publisherAmerican Society of Civil Engineers
    titleExperimental and Numerical Studies of Circular Footing Resting on Confined Granular Subgrade Adjacent to Slope
    typeJournal Paper
    journal volume16
    journal issue1
    journal titleInternational Journal of Geomechanics
    identifier doi10.1061/(ASCE)GM.1943-5622.0000500
    page04015028
    treeInternational Journal of Geomechanics:;2016:;Volume ( 016 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian