End of the Service Life of Ceramic Cladding: Lessons from the Girasol Building in MadridSource: Journal of Performance of Constructed Facilities:;2017:;Volume ( 031 ):;issue: 002Author:Pedro Lima Gaspar
DOI: 10.1061/(ASCE)CF.1943-5509.0000950Publisher: American Society of Civil Engineers
Abstract: In the summer of 2015, the existing ceramic cladding of the Girasol Building in Madrid went through an inspection campaign that left all underlying occurrences of detachment exposed. The community of neighbors then decided to renew the façade, therefore marking the end of the service life (SL) of the cladding. A visual assessment of the façade was thus made in order to quantify its overall condition after 49 years of SL. These data are used to provide real life feedback and discuss existing methods of SL estimation. The information gathered confirms that 50 years (or 100 aging cycles) are accurate estimations for the SL of ceramic claddings for a 20% level of degradation. Conclusions are also reached regarding the relationship between SL, threshold limits, and their dependency on human decision making processes.
|
Collections
Show full item record
| contributor author | Pedro Lima Gaspar | |
| date accessioned | 2017-12-30T12:59:20Z | |
| date available | 2017-12-30T12:59:20Z | |
| date issued | 2017 | |
| identifier other | %28ASCE%29CF.1943-5509.0000950.pdf | |
| identifier uri | http://138.201.223.254:8080/yetl1/handle/yetl/4244200 | |
| description abstract | In the summer of 2015, the existing ceramic cladding of the Girasol Building in Madrid went through an inspection campaign that left all underlying occurrences of detachment exposed. The community of neighbors then decided to renew the façade, therefore marking the end of the service life (SL) of the cladding. A visual assessment of the façade was thus made in order to quantify its overall condition after 49 years of SL. These data are used to provide real life feedback and discuss existing methods of SL estimation. The information gathered confirms that 50 years (or 100 aging cycles) are accurate estimations for the SL of ceramic claddings for a 20% level of degradation. Conclusions are also reached regarding the relationship between SL, threshold limits, and their dependency on human decision making processes. | |
| publisher | American Society of Civil Engineers | |
| title | End of the Service Life of Ceramic Cladding: Lessons from the Girasol Building in Madrid | |
| type | Journal Paper | |
| journal volume | 31 | |
| journal issue | 2 | |
| journal title | Journal of Performance of Constructed Facilities | |
| identifier doi | 10.1061/(ASCE)CF.1943-5509.0000950 | |
| page | 04016088 | |
| tree | Journal of Performance of Constructed Facilities:;2017:;Volume ( 031 ):;issue: 002 | |
| contenttype | Fulltext |