    Errors in Calculating Anterior–Posterior Tibial Contact Locations in Total Knee Arthroplasty Using Three-Dimensional Model to Two-Dimensional Image Registration in Radiographs: An In Vitro Study of Two Methods

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 012::page 121003
    Author:
    Ross
    ,
    Derrick S.;Howell
    ,
    Stephen M.;Hull
    ,
    Maury L.
    DOI: 10.1115/1.4037632
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Knowledge of anterior–posterior (A-P) tibial contact locations provides an objective assessment of the relative motion of the tibia on the femur following total knee arthroplasty (TKA), which can be used to compare the effects of different components, surgical techniques, and alignment goals on knee function in vivo. Both the lowest point method and the penetration method have been used to calculate A-P tibial contact locations using three-dimensional (3D) model to two-dimensional (2D) image registration. The primary objective of this study was to quantify errors in calculating the A-P tibial contact location using the lowest point and penetration methods because the errors in calculating the A-P tibial contact locations using these two methods are unknown. The A-P tibial contact locations were calculated with the two methods and simultaneously measured with a tibial force sensor in ten fresh-frozen cadaveric knee specimens with a TKA. Single-plane radiographs of the knee specimens were acquired at 0 deg, 30 deg, 60 deg, and 90 deg of flexion in neutrally, internally, and externally rotated orientations. While the radiographs were exposed, reference A-P tibial contact locations were simultaneously collected using the tibial force sensor to be compared to the calculated A-P tibial contact locations. The overall root-mean-squared-errors (RMSEs) in the A-P tibial contact location calculated with the lowest point method, the penetration method with penetration, and penetration method without penetration were 5.5 mm, 3.6 mm, and 8.9 mm, respectively. The overall RMSE was lowest for the penetration method with penetration, making it the superior method for calculating A-P tibial contact locations.
    • Download: (614.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Errors in Calculating Anterior–Posterior Tibial Contact Locations in Total Knee Arthroplasty Using Three-Dimensional Model to Two-Dimensional Image Registration in Radiographs: An In Vitro Study of Two Methods

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4242934
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorRoss
    contributor authorDerrick S.;Howell
    contributor authorStephen M.;Hull
    contributor authorMaury L.
    date accessioned2017-12-30T11:43:54Z
    date available2017-12-30T11:43:54Z
    date copyright9/28/2017 12:00:00 AM
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_12_121003.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4242934
    description abstractKnowledge of anterior–posterior (A-P) tibial contact locations provides an objective assessment of the relative motion of the tibia on the femur following total knee arthroplasty (TKA), which can be used to compare the effects of different components, surgical techniques, and alignment goals on knee function in vivo. Both the lowest point method and the penetration method have been used to calculate A-P tibial contact locations using three-dimensional (3D) model to two-dimensional (2D) image registration. The primary objective of this study was to quantify errors in calculating the A-P tibial contact location using the lowest point and penetration methods because the errors in calculating the A-P tibial contact locations using these two methods are unknown. The A-P tibial contact locations were calculated with the two methods and simultaneously measured with a tibial force sensor in ten fresh-frozen cadaveric knee specimens with a TKA. Single-plane radiographs of the knee specimens were acquired at 0 deg, 30 deg, 60 deg, and 90 deg of flexion in neutrally, internally, and externally rotated orientations. While the radiographs were exposed, reference A-P tibial contact locations were simultaneously collected using the tibial force sensor to be compared to the calculated A-P tibial contact locations. The overall root-mean-squared-errors (RMSEs) in the A-P tibial contact location calculated with the lowest point method, the penetration method with penetration, and penetration method without penetration were 5.5 mm, 3.6 mm, and 8.9 mm, respectively. The overall RMSE was lowest for the penetration method with penetration, making it the superior method for calculating A-P tibial contact locations.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleErrors in Calculating Anterior–Posterior Tibial Contact Locations in Total Knee Arthroplasty Using Three-Dimensional Model to Two-Dimensional Image Registration in Radiographs: An In Vitro Study of Two Methods
    typeJournal Paper
    journal volume139
    journal issue12
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4037632
    journal fristpage121003
    journal lastpage121003-10
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 012
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian