    Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter

    Source: Journal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 009
    Author:
    Agathoklis Giaralis
    ,
    Francesco Petrini
    DOI: 10.1061/(ASCE)ST.1943-541X.0001863
    Publisher: American Society of Civil Engineers
    Abstract: In this paper, the classical linear tuned mass damper (TMD) is coupled with an inerter, a two-terminal device resisting the relative acceleration of its terminals, in various tuned mass-damper-inerter (TMDI) topologies to suppress excessive wind-induced oscillations in tall buildings causing occupant discomfort. A parametric numerical study is undertaken involving a top-floor-TMD-equipped planar frame accurately capturing the in-plane dynamic behavior of a 74-story benchmark building exposed to a quasi-stationary spatially correlated wind-force field accounting for vortex shedding effects in the across-wind direction. It is found that the TMDI reduces peak top-floor acceleration more effectively than the TMD by considering smaller attached-mass values, and TMDI topologies in which the inerter spans more stories in linking the attached mass to the host structure. Moreover, the inclusion of the inerter dramatically reduces the TMD stroke, and it has been verified that the magnitude of the developing inerter forces can be readily accommodated by the host structure. Pertinent illustrative examples are included showcasing that the TMDI meets code-prescribed serviceability design requirements for new tall buildings using significantly smaller attached mass compared with the TMD, and that inerter devices can be used to upgrade the performance of existing TMD-equipped tall buildings without changing the attached mass.
    • Download: (1.075Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4242551
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorAgathoklis Giaralis
    contributor authorFrancesco Petrini
    date accessioned2017-12-16T09:24:21Z
    date available2017-12-16T09:24:21Z
    date issued2017
    identifier other%28ASCE%29ST.1943-541X.0001863.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4242551
    description abstractIn this paper, the classical linear tuned mass damper (TMD) is coupled with an inerter, a two-terminal device resisting the relative acceleration of its terminals, in various tuned mass-damper-inerter (TMDI) topologies to suppress excessive wind-induced oscillations in tall buildings causing occupant discomfort. A parametric numerical study is undertaken involving a top-floor-TMD-equipped planar frame accurately capturing the in-plane dynamic behavior of a 74-story benchmark building exposed to a quasi-stationary spatially correlated wind-force field accounting for vortex shedding effects in the across-wind direction. It is found that the TMDI reduces peak top-floor acceleration more effectively than the TMD by considering smaller attached-mass values, and TMDI topologies in which the inerter spans more stories in linking the attached mass to the host structure. Moreover, the inclusion of the inerter dramatically reduces the TMD stroke, and it has been verified that the magnitude of the developing inerter forces can be readily accommodated by the host structure. Pertinent illustrative examples are included showcasing that the TMDI meets code-prescribed serviceability design requirements for new tall buildings using significantly smaller attached mass compared with the TMD, and that inerter devices can be used to upgrade the performance of existing TMD-equipped tall buildings without changing the attached mass.
    publisherAmerican Society of Civil Engineers
    titleWind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
    typeJournal Paper
    journal volume143
    journal issue9
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001863
    treeJournal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian