    Case Study of Trombe Wall Inducing Natural Ventilation through Cooled Basement Air to Meet Space Cooling Needs

    Source: Journal of Energy Engineering:;2017:;Volume ( 143 ):;issue: 002
    Author:
    Mazen Badawiyeh
    ,
    Nesreen Ghaddar
    ,
    Kamel Ghali
    DOI: 10.1061/(ASCE)EY.1943-7897.0000393
    Publisher: American Society of Civil Engineers
    Abstract: Underground spaces normally are at cooler air temperature than ambient air temperature because of earth-sheltered walls. This cooler air can be circulated to occupied spaces using a solar chimney effect to exhaust air from the basement to where it is needed. This work aims to study the viability of using natural ventilation induced by a Trombe wall to draw fresh air from underground basement floors for space cooling in the dry desert climate. Outdoor air is delivered to the basement through an earth tube. A numerical model integrating thermal models of the basement space and the occupied zone, and the Trombe wall is used to predict the air temperature variation with time in the occupied space air temperature and to predict thermal comfort. The feasibility of implementing the proposed system is assessed in a case study of a residence in the inland dry desert climate of Lebanon during the summer. It was found that the proposed system achieved thermally comfortable conditions at 80% acceptability for a considerable number of hours without the need for mechanical ventilation (83.3% in June and 58.3% in August). The electric energy consumption of the system over summer (June through September) was estimated at 7.71  kW·h/m2 of floor area.
    • Download: (2.328Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Case Study of Trombe Wall Inducing Natural Ventilation through Cooled Basement Air to Meet Space Cooling Needs

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4240341
    Collections
    • Journal of Energy Engineering

    Show full item record

    contributor authorMazen Badawiyeh
    contributor authorNesreen Ghaddar
    contributor authorKamel Ghali
    date accessioned2017-12-16T09:14:21Z
    date available2017-12-16T09:14:21Z
    date issued2017
    identifier other%28ASCE%29EY.1943-7897.0000393.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4240341
    description abstractUnderground spaces normally are at cooler air temperature than ambient air temperature because of earth-sheltered walls. This cooler air can be circulated to occupied spaces using a solar chimney effect to exhaust air from the basement to where it is needed. This work aims to study the viability of using natural ventilation induced by a Trombe wall to draw fresh air from underground basement floors for space cooling in the dry desert climate. Outdoor air is delivered to the basement through an earth tube. A numerical model integrating thermal models of the basement space and the occupied zone, and the Trombe wall is used to predict the air temperature variation with time in the occupied space air temperature and to predict thermal comfort. The feasibility of implementing the proposed system is assessed in a case study of a residence in the inland dry desert climate of Lebanon during the summer. It was found that the proposed system achieved thermally comfortable conditions at 80% acceptability for a considerable number of hours without the need for mechanical ventilation (83.3% in June and 58.3% in August). The electric energy consumption of the system over summer (June through September) was estimated at 7.71  kW·h/m2 of floor area.
    publisherAmerican Society of Civil Engineers
    titleCase Study of Trombe Wall Inducing Natural Ventilation through Cooled Basement Air to Meet Space Cooling Needs
    typeJournal Paper
    journal volume143
    journal issue2
    journal titleJournal of Energy Engineering
    identifier doi10.1061/(ASCE)EY.1943-7897.0000393
    treeJournal of Energy Engineering:;2017:;Volume ( 143 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian