YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Use of TDR to Compare Rising Damp in Three Tuff Walls Made with Different Mortars

    Source: Journal of Materials in Civil Engineering:;2017:;Volume ( 029 ):;issue: 004
    Author:
    Rosa Agliata
    ,
    Luigi Mollo
    ,
    Roberto Greco
    DOI: 10.1061/(ASCE)MT.1943-5533.0001794
    Publisher: American Society of Civil Engineers
    Abstract: Capillary rise is a serious phenomenon that may have potentially devastating consequences within buildings (biological corrosion, worsening of indoor comfort parameters, worsening of thermal resistance, etc.). Therefore, measuring moisture in building structures is still a current research issue and time domain reflectometry (TDR) is considered one of the most-effective nondestructive methods for moisture estimation in porous media. This paper reports a research examining the effects of different kinds of mortar on the capillary rise in yellow volcanic tuff walls. To this aim, three model walls were built with tuff and three different kinds of mortar (a traditional cement lime mortar and two premixed mortars, one of which was specifically designed to prevent capillary rise), and then instrumented with TDR probes, to carry out continuous monitoring of volumetric water content without the need of sampling or material destruction. Preliminarily, the calibration relationship linking relative dielectric permittivity, provided by TDR measurement, with volumetric water content, measured gravimetrically, has been experimentally determined in laboratory with yellow tuff specimens. The obtained results suggest that TDR can be suitable to reliable in situ monitoring of moisture dynamics in tuff walls in a nondestructive way. The velocity and height of capillary rise resulted strongly affected by the adopted type of mortar. In particular, the wall made with simple premixed mortar was characterized by the highest water absorptivity, whereas the one made with the specific antirise mortar showed the lowest moisture increase. The obtained results also allowed a physical interpretation of the behavior of water uptake related to the different types of mortars.
    • Download: (440.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Use of TDR to Compare Rising Damp in Three Tuff Walls Made with Different Mortars

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4237862
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorRosa Agliata
    contributor authorLuigi Mollo
    contributor authorRoberto Greco
    date accessioned2017-12-16T09:02:47Z
    date available2017-12-16T09:02:47Z
    date issued2017
    identifier other%28ASCE%29MT.1943-5533.0001794.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4237862
    description abstractCapillary rise is a serious phenomenon that may have potentially devastating consequences within buildings (biological corrosion, worsening of indoor comfort parameters, worsening of thermal resistance, etc.). Therefore, measuring moisture in building structures is still a current research issue and time domain reflectometry (TDR) is considered one of the most-effective nondestructive methods for moisture estimation in porous media. This paper reports a research examining the effects of different kinds of mortar on the capillary rise in yellow volcanic tuff walls. To this aim, three model walls were built with tuff and three different kinds of mortar (a traditional cement lime mortar and two premixed mortars, one of which was specifically designed to prevent capillary rise), and then instrumented with TDR probes, to carry out continuous monitoring of volumetric water content without the need of sampling or material destruction. Preliminarily, the calibration relationship linking relative dielectric permittivity, provided by TDR measurement, with volumetric water content, measured gravimetrically, has been experimentally determined in laboratory with yellow tuff specimens. The obtained results suggest that TDR can be suitable to reliable in situ monitoring of moisture dynamics in tuff walls in a nondestructive way. The velocity and height of capillary rise resulted strongly affected by the adopted type of mortar. In particular, the wall made with simple premixed mortar was characterized by the highest water absorptivity, whereas the one made with the specific antirise mortar showed the lowest moisture increase. The obtained results also allowed a physical interpretation of the behavior of water uptake related to the different types of mortars.
    publisherAmerican Society of Civil Engineers
    titleUse of TDR to Compare Rising Damp in Three Tuff Walls Made with Different Mortars
    typeJournal Paper
    journal volume29
    journal issue4
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0001794
    treeJournal of Materials in Civil Engineering:;2017:;Volume ( 029 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian