    Experimentally Measured Effects of Incidence Angle on the Adiabatic and Overall Effectiveness of a Fully Cooled Turbine Airfoil With Shaped Showerhead Holes

    Source: Journal of Turbomachinery:;2017:;volume( 139 ):;issue: 009::page 91007
    Author:
    Chavez, Kyle
    ,
    Slavens, Thomas N.
    ,
    Bogard, David
    DOI: 10.1115/1.4036200
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Manufacturing and assembly variation can lead to shifts in the inlet flow incidence angles of a rotating turbine airfoil row. Understanding the sensitivity of the adiabatic film cooling effectiveness to a range of inlet conditions is necessary to verify the robustness of a cooling design. In order to investigate the effects of inlet flow incidence angles, adiabatic and overall effectiveness data were measured in a low speed linear cascade at 0 deg and 10 deg of the designed operating condition. Tests were completed at an inlet Reynolds number of Re = 120,000 and a turbulence intensity of Tu = 5% at the leading edge of the test article. Particle image velocimetry was used to verify the incident flow angle for each angle studied. The test section was first adjusted so that the pressure distribution and stagnation line of the airfoil matched those predicted by an aerodynamic computational fluid dynamics (CFD) model. IR thermography was then used to measure the adiabatic effectiveness levels of the fully cooled airfoil model with nine rows of shaped holes of varying construction and feed delivery. Measurements were taken over a range of blowing ratios and at a density ratio of DR = 1.23. This process was repeated for the two incidence angles measured, while the inlet pressure to the airfoil model was held constant for these incidence angle changes. Differences in laterally adiabatic effectiveness across the airfoil model were most evident in the showerhead, with changes as large as 0.2. The effect persisted most strongly at s/D = ±35 downstream of the stagnation row of holes, but was visible over the whole viewable area of 160 s/D. The effect was due to the stagnation line affecting the film at the showerhead row. Due to this effect, the showerhead was investigated in detail, including the effects of the stagnation line shift as well as the influence of the incidence angle on the overall effectiveness of the showerhead region. It was found that the stagnation line has the tendency to dramatically increase the near-hole adiabatic effectiveness levels when positioned within the breakout footprint of the hole. The effect persisted for the overall effectiveness study, since the hole spacing for this particular configuration was wide enough that the through hole convection was not completely dominant. This is the first study to present measured effectiveness values over both the pressure- and suction-side surfaces of a fully cooled airfoil for appreciably off-nominal incidence angles as well as examine adiabatic and overall effectiveness levels for a conical stagnation row of holes.
    • Download: (4.004Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimentally Measured Effects of Incidence Angle on the Adiabatic and Overall Effectiveness of a Fully Cooled Turbine Airfoil With Shaped Showerhead Holes

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4236106
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorChavez, Kyle
    contributor authorSlavens, Thomas N.
    contributor authorBogard, David
    date accessioned2017-11-25T07:19:55Z
    date available2017-11-25T07:19:55Z
    date copyright2017/19/4
    date issued2017
    identifier issn0889-504X
    identifier otherturbo_139_09_091007.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4236106
    description abstractManufacturing and assembly variation can lead to shifts in the inlet flow incidence angles of a rotating turbine airfoil row. Understanding the sensitivity of the adiabatic film cooling effectiveness to a range of inlet conditions is necessary to verify the robustness of a cooling design. In order to investigate the effects of inlet flow incidence angles, adiabatic and overall effectiveness data were measured in a low speed linear cascade at 0 deg and 10 deg of the designed operating condition. Tests were completed at an inlet Reynolds number of Re = 120,000 and a turbulence intensity of Tu = 5% at the leading edge of the test article. Particle image velocimetry was used to verify the incident flow angle for each angle studied. The test section was first adjusted so that the pressure distribution and stagnation line of the airfoil matched those predicted by an aerodynamic computational fluid dynamics (CFD) model. IR thermography was then used to measure the adiabatic effectiveness levels of the fully cooled airfoil model with nine rows of shaped holes of varying construction and feed delivery. Measurements were taken over a range of blowing ratios and at a density ratio of DR = 1.23. This process was repeated for the two incidence angles measured, while the inlet pressure to the airfoil model was held constant for these incidence angle changes. Differences in laterally adiabatic effectiveness across the airfoil model were most evident in the showerhead, with changes as large as 0.2. The effect persisted most strongly at s/D = ±35 downstream of the stagnation row of holes, but was visible over the whole viewable area of 160 s/D. The effect was due to the stagnation line affecting the film at the showerhead row. Due to this effect, the showerhead was investigated in detail, including the effects of the stagnation line shift as well as the influence of the incidence angle on the overall effectiveness of the showerhead region. It was found that the stagnation line has the tendency to dramatically increase the near-hole adiabatic effectiveness levels when positioned within the breakout footprint of the hole. The effect persisted for the overall effectiveness study, since the hole spacing for this particular configuration was wide enough that the through hole convection was not completely dominant. This is the first study to present measured effectiveness values over both the pressure- and suction-side surfaces of a fully cooled airfoil for appreciably off-nominal incidence angles as well as examine adiabatic and overall effectiveness levels for a conical stagnation row of holes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimentally Measured Effects of Incidence Angle on the Adiabatic and Overall Effectiveness of a Fully Cooled Turbine Airfoil With Shaped Showerhead Holes
    typeJournal Paper
    journal volume139
    journal issue9
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.4036200
    journal fristpage91007
    journal lastpage091007-10
    treeJournal of Turbomachinery:;2017:;volume( 139 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian