YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Experimental Study of a Solar Air Heater With a New Arrangement of Transverse Longitudinal Baffles

    Source: Journal of Solar Energy Engineering:;2017:;volume( 139 ):;issue: 003::page 31004
    Author:
    Mahmood, Afaq Jasim
    DOI: 10.1115/1.4035756
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This study presents a new design for improving the convection heat transfer coefficients of double-pass solar air heater. Three cases were described by using a different number of transverse baffles (three, five, and seven) in the lower channel of the collectors; steel mesh sheets were also used to enlarge the heat transfer area. All collectors have a space of 25 mm between its glass covers and a 50 mm depth of air channel. Furthermore, this work examined the effect of air flow rate and baffles number on device's thermal efficiency and outlet temperature. The experimental results indicate raises in the thermal efficiency as the air flow rate goes from 0.011 kg/s to 0.038 kg/s. A maximum efficiency of 68% was obtained from the case of seven baffles at the air flow rate of 0.038 kg/s. Moreover, the difference between collector's inlet and outlet temperatures, ΔT, indicated an inverse relationship with air flow rate. Thus, the results show ΔT increases as the air flow rate reduced. The maximum temperature difference recorded was 54 °C, which achieved using seven baffled solar air heater at 0.011 kg/s air flow rate in the middle of the day. It has also been found that thermal efficiency of double-pass solar air heater is greater than single-pass solar air heater, using same air flow rate and number of baffles. Finally, the pressure drop associated with increasing the number of baffles and air flow rate was deliberated.
    • Download: (2.029Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Study of a Solar Air Heater With a New Arrangement of Transverse Longitudinal Baffles

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4235714
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorMahmood, Afaq Jasim
    date accessioned2017-11-25T07:19:17Z
    date available2017-11-25T07:19:17Z
    date copyright2017/8/2
    date issued2017
    identifier issn0199-6231
    identifier othersol_139_03_031004.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235714
    description abstractThis study presents a new design for improving the convection heat transfer coefficients of double-pass solar air heater. Three cases were described by using a different number of transverse baffles (three, five, and seven) in the lower channel of the collectors; steel mesh sheets were also used to enlarge the heat transfer area. All collectors have a space of 25 mm between its glass covers and a 50 mm depth of air channel. Furthermore, this work examined the effect of air flow rate and baffles number on device's thermal efficiency and outlet temperature. The experimental results indicate raises in the thermal efficiency as the air flow rate goes from 0.011 kg/s to 0.038 kg/s. A maximum efficiency of 68% was obtained from the case of seven baffles at the air flow rate of 0.038 kg/s. Moreover, the difference between collector's inlet and outlet temperatures, ΔT, indicated an inverse relationship with air flow rate. Thus, the results show ΔT increases as the air flow rate reduced. The maximum temperature difference recorded was 54 °C, which achieved using seven baffled solar air heater at 0.011 kg/s air flow rate in the middle of the day. It has also been found that thermal efficiency of double-pass solar air heater is greater than single-pass solar air heater, using same air flow rate and number of baffles. Finally, the pressure drop associated with increasing the number of baffles and air flow rate was deliberated.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleExperimental Study of a Solar Air Heater With a New Arrangement of Transverse Longitudinal Baffles
    typeJournal Paper
    journal volume139
    journal issue3
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4035756
    journal fristpage31004
    journal lastpage031004-12
    treeJournal of Solar Energy Engineering:;2017:;volume( 139 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian