    Increasing Efficiency in the Extraction of Solar Heat Stored Underground With Perturb-and-Observe Control

    Source: Journal of Solar Energy Engineering:;2017:;volume( 139 ):;issue: 002::page 21014
    Author:
    de Nardin, Carlos R.
    ,
    Fernandes, Felipe T.
    ,
    Longo, Adriano J.
    ,
    Lima, Luciano P.
    ,
    Farret, Felix A.
    ,
    Cruz, Dário R.
    DOI: 10.1115/1.4035329
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper describes a perturb-and-observe (P&O) control aiming to increase the heat exchange between solar heat stored underground and the ambient of a single conditioned room without any heat pump. This P&O control increases or decreases the water flow rate through an underground hosepipe heat exchanger. With this purpose, two power converters were used to activate, respectively, a low power water pump and a fan coil so as to keep the room within the limits of a reference temperature range (between 18 °C and 24 °C). Outside these limits, the P&O control searches for the best heat exchange between the ambient room and the underground soil and, when inside these limits, the water pump and fan coil are turned off. Two identical experimental rooms, referred in this study as “reference” and “test” rooms, had their temperatures measured every 1-min during winter and summer. For comparison purposes, the reference room was left at its natural conditions without any air conditioning. The experimental results show a remarkable improvement in the heat exchange and a considerable reduction in power demand when using the P&O control. As a result, it was obtained an energy saving of approximately 45% in one summer day and 22% in one winter day. It is important to point out that this paper refers, strictly, to the description of a P&O control for heat exchange systems involving solar heat stored underground in a single room.
    • Download: (1.533Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Increasing Efficiency in the Extraction of Solar Heat Stored Underground With Perturb-and-Observe Control

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4235706
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorde Nardin, Carlos R.
    contributor authorFernandes, Felipe T.
    contributor authorLongo, Adriano J.
    contributor authorLima, Luciano P.
    contributor authorFarret, Felix A.
    contributor authorCruz, Dário R.
    date accessioned2017-11-25T07:19:16Z
    date available2017-11-25T07:19:16Z
    date copyright2016/22/12
    date issued2017
    identifier issn0199-6231
    identifier othersol_139_02_021014.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235706
    description abstractThis paper describes a perturb-and-observe (P&O) control aiming to increase the heat exchange between solar heat stored underground and the ambient of a single conditioned room without any heat pump. This P&O control increases or decreases the water flow rate through an underground hosepipe heat exchanger. With this purpose, two power converters were used to activate, respectively, a low power water pump and a fan coil so as to keep the room within the limits of a reference temperature range (between 18 °C and 24 °C). Outside these limits, the P&O control searches for the best heat exchange between the ambient room and the underground soil and, when inside these limits, the water pump and fan coil are turned off. Two identical experimental rooms, referred in this study as “reference” and “test” rooms, had their temperatures measured every 1-min during winter and summer. For comparison purposes, the reference room was left at its natural conditions without any air conditioning. The experimental results show a remarkable improvement in the heat exchange and a considerable reduction in power demand when using the P&O control. As a result, it was obtained an energy saving of approximately 45% in one summer day and 22% in one winter day. It is important to point out that this paper refers, strictly, to the description of a P&O control for heat exchange systems involving solar heat stored underground in a single room.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIncreasing Efficiency in the Extraction of Solar Heat Stored Underground With Perturb-and-Observe Control
    typeJournal Paper
    journal volume139
    journal issue2
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4035329
    journal fristpage21014
    journal lastpage021014-7
    treeJournal of Solar Energy Engineering:;2017:;volume( 139 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian