YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Nuclear Engineering and Radiation Science
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Benchmarking the Real-Time Core Model for VVER-1000 Simulator Application on Asymmetric Core Load

    Source: Journal of Nuclear Engineering and Radiation Science:;2017:;volume( 003 ):;issue: 003::page 31005
    Author:
    Georgieva, Emiliya
    ,
    Dinkov, Yavor
    ,
    Ivanov, Kostadin
    DOI: 10.1115/1.4035550
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The aim of this paper is to summarize authors' experience in adaptation of an existing plant-specific VVER-1000/V320 model for simulation of a rare example of a Kalinin 3 nuclear power plant (NPP) transient of “switching-off of one of the four operating main circulation pumps at nominal reactor power” with an asymmetric core configuration. The fidelity and accuracy of simulation with emphasis on reactor core model is illustrated through comparison with plant-specific data. Simulation results concerning fuel assembly (FA) power and axial power distribution during the transient are compared with records from Kalinin 3 in-core monitoring system (ICMS). Main operating parameters of nuclear steam supply system of a VVER-1000/V320 series units vary to a considerable degree. While Kalinin 3 benchmark specification contains very good description of the transient, as well as record of many parameters of the unit, the document provides only superficial description of the reference unit. In such a case, an approach based on a “generic” V320 model by default introduces deviations which are difficult to quantify. There are several examples which warrant discussion. Some of the most important lessons learned are as follows. (1) individual characteristics of all the main circulation pumps and the reactor coolant loops are quite important for the quality of simulation and should be accounted for in the model; (2) variations in fuel assembly characteristics should be accounted for not only in terms of macroscopic cross section library but also in terms of local pressure loss coefficients and mixing factors in the case of mixed core loads; (3) comprehensive plant-specific model of dynamic response of instrumentation and control (I&C) systems is a necessity; dynamic characteristics of individual measurement channels (nuclear instrumentation, pressure, temperature) should be accounted for; and (4) comprehensive plant-specific model of balance-of-plant equipment, instrumentation, and control is a necessity. Above requirements impose a difficult task to comply with. Nevertheless, any individual nuclear power unit is supposed to maintain a detailed design database and data requirements for plant-specific model development should be considered.
    • Download: (6.405Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Benchmarking the Real-Time Core Model for VVER-1000 Simulator Application on Asymmetric Core Load

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4235344
    Collections
    • Journal of Nuclear Engineering and Radiation Science

    Show full item record

    contributor authorGeorgieva, Emiliya
    contributor authorDinkov, Yavor
    contributor authorIvanov, Kostadin
    date accessioned2017-11-25T07:18:42Z
    date available2017-11-25T07:18:42Z
    date copyright2017/25/5
    date issued2017
    identifier issn2332-8983
    identifier otherners_003_03_031005.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235344
    description abstractThe aim of this paper is to summarize authors' experience in adaptation of an existing plant-specific VVER-1000/V320 model for simulation of a rare example of a Kalinin 3 nuclear power plant (NPP) transient of “switching-off of one of the four operating main circulation pumps at nominal reactor power” with an asymmetric core configuration. The fidelity and accuracy of simulation with emphasis on reactor core model is illustrated through comparison with plant-specific data. Simulation results concerning fuel assembly (FA) power and axial power distribution during the transient are compared with records from Kalinin 3 in-core monitoring system (ICMS). Main operating parameters of nuclear steam supply system of a VVER-1000/V320 series units vary to a considerable degree. While Kalinin 3 benchmark specification contains very good description of the transient, as well as record of many parameters of the unit, the document provides only superficial description of the reference unit. In such a case, an approach based on a “generic” V320 model by default introduces deviations which are difficult to quantify. There are several examples which warrant discussion. Some of the most important lessons learned are as follows. (1) individual characteristics of all the main circulation pumps and the reactor coolant loops are quite important for the quality of simulation and should be accounted for in the model; (2) variations in fuel assembly characteristics should be accounted for not only in terms of macroscopic cross section library but also in terms of local pressure loss coefficients and mixing factors in the case of mixed core loads; (3) comprehensive plant-specific model of dynamic response of instrumentation and control (I&C) systems is a necessity; dynamic characteristics of individual measurement channels (nuclear instrumentation, pressure, temperature) should be accounted for; and (4) comprehensive plant-specific model of balance-of-plant equipment, instrumentation, and control is a necessity. Above requirements impose a difficult task to comply with. Nevertheless, any individual nuclear power unit is supposed to maintain a detailed design database and data requirements for plant-specific model development should be considered.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleBenchmarking the Real-Time Core Model for VVER-1000 Simulator Application on Asymmetric Core Load
    typeJournal Paper
    journal volume3
    journal issue3
    journal titleJournal of Nuclear Engineering and Radiation Science
    identifier doi10.1115/1.4035550
    journal fristpage31005
    journal lastpage031005-10
    treeJournal of Nuclear Engineering and Radiation Science:;2017:;volume( 003 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian