    Archive

    Assessing the Importance of Surgeon Hand Anthropometry on the Design of Medical Devices

    Source: Journal of Medical Devices:;2017:;volume( 011 ):;issue: 004::page 41004
    Author:
    Stellon, Michael
    ,
    Seils, Drew
    ,
    Mauro, Christine
    DOI: 10.1115/1.4037257
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Improperly designed medical devices can induce unwanted biomechanical stressors on their users, impacting health and career longevity. Despite this, manufacturers struggle to balance device design with the growing female surgeon population. We have applied anthropometry to a population of surgeon hands as an alternative to preferred glove size. Correlations to physical dimensions of two laparoscopic staplers were assessed. Five anthropometric measurements were taken from dominant hands of surgeons. These measurements were selected with the goal of comparing resulting data to published anthropometry studies and assessing correlation to preferred glove size and instrument design. The trigger reach of the two laparoscopic staplers were measured to assess suitability among the surgeon population surveyed. Fifty eight surgeons (50 male, 8 female), average glove size 7.5 and 6.0, were measured. Data indicate that male surgeons had significantly larger hands than female. Hand circumference displayed a relatively strong positive correlation with preferred glove size (0.799, R2 = 63.9%); other measurements did not. The trigger span of one stapler was found suitable for only 78.2% of male and 30.9% of female surgeons, based on comparisons with anthropometry of the surveyed population. Anthropometry should be used to characterize surgeon hands instead of preferred glove size. Also, from the limited scope of this research, discrepancies exist between the size of the surgeon hand and the devices designed for their use. The use of inappropriately designed instrumentation can cause musculoskeletal injury, decreased productivity, and shortened careers. Manufacturers would benefit by consulting anthropometry databases to develop products.
    • Download: (446.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Assessing the Importance of Surgeon Hand Anthropometry on the Design of Medical Devices

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4235251
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorStellon, Michael
    contributor authorSeils, Drew
    contributor authorMauro, Christine
    date accessioned2017-11-25T07:18:34Z
    date available2017-11-25T07:18:34Z
    date copyright2017/17/8
    date issued2017
    identifier issn1932-6181
    identifier othermed_011_04_041004.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235251
    description abstractImproperly designed medical devices can induce unwanted biomechanical stressors on their users, impacting health and career longevity. Despite this, manufacturers struggle to balance device design with the growing female surgeon population. We have applied anthropometry to a population of surgeon hands as an alternative to preferred glove size. Correlations to physical dimensions of two laparoscopic staplers were assessed. Five anthropometric measurements were taken from dominant hands of surgeons. These measurements were selected with the goal of comparing resulting data to published anthropometry studies and assessing correlation to preferred glove size and instrument design. The trigger reach of the two laparoscopic staplers were measured to assess suitability among the surgeon population surveyed. Fifty eight surgeons (50 male, 8 female), average glove size 7.5 and 6.0, were measured. Data indicate that male surgeons had significantly larger hands than female. Hand circumference displayed a relatively strong positive correlation with preferred glove size (0.799, R2 = 63.9%); other measurements did not. The trigger span of one stapler was found suitable for only 78.2% of male and 30.9% of female surgeons, based on comparisons with anthropometry of the surveyed population. Anthropometry should be used to characterize surgeon hands instead of preferred glove size. Also, from the limited scope of this research, discrepancies exist between the size of the surgeon hand and the devices designed for their use. The use of inappropriately designed instrumentation can cause musculoskeletal injury, decreased productivity, and shortened careers. Manufacturers would benefit by consulting anthropometry databases to develop products.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAssessing the Importance of Surgeon Hand Anthropometry on the Design of Medical Devices
    typeJournal Paper
    journal volume11
    journal issue4
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4037257
    journal fristpage41004
    journal lastpage041004-6
    treeJournal of Medical Devices:;2017:;volume( 011 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian