    pneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor

    Source: Journal of Medical Devices:;2017:;volume( 011 ):;issue: 001::page 11010
    Author:
    Rahman, Tariq
    ,
    Page, Ralph
    ,
    Page, Christopher
    ,
    Bonnefoy, Jean-Remy
    ,
    Cox, Tim
    ,
    Shaffer, Thomas H.
    DOI: 10.1115/1.4035546
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Objective pulmonary function (PF) evaluation is essential for the diagnosis, monitoring, and management of many pediatric respiratory diseases as seen in the emergency room, intensive care, and outpatient settings. In this paper, the development and testing of a new noninvasive PF instrument, pneuRIPTM, which utilizes respiratory inductance plethysmography (RIP) are discussed. The pneuRIPTM hardware includes a small circuit board that connects to the RIP bands and measures and wirelessly transmits the band inductance data to any designated wirelessly connected tablet. The software provides indices of respiratory work presented instantaneously in a user-friendly graphical user interface on the tablet. The system was tested with ten normal children and compared with an existing system, Respitrace (Sensormedics, Yorba Linda, CA), under normal and loaded breathing conditions. Under normal breathing, the percentage differences between the two systems were 2.9% for labored breathing index (LBI), 31.8% for phase angle (Φ), 4.8% for percentage rib cage (RC%), and 26.7% for respiratory rate (BPM). Under loaded breathing, the percentage differences between the two systems were 1.6% for LBI, 4.1% for Φ, 8.5% for RC%, and 52.7% for BPM. For LBI, Φ, and RC%, the two systems were in general agreement. For BPM the pneuRIPTM is shown to be more accurate than the respitrace when compared to manually counting the breaths: 13.2% versus 36.4% accuracy for normal breathing and 16.9% versus 60.7% accuracy for breathing under load, respectively.
    • Download: (1.647Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      pneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4235198
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorRahman, Tariq
    contributor authorPage, Ralph
    contributor authorPage, Christopher
    contributor authorBonnefoy, Jean-Remy
    contributor authorCox, Tim
    contributor authorShaffer, Thomas H.
    date accessioned2017-11-25T07:18:29Z
    date available2017-11-25T07:18:29Z
    date copyright2017/24/1
    date issued2017
    identifier issn1932-6181
    identifier othermed_011_01_011010.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235198
    description abstractObjective pulmonary function (PF) evaluation is essential for the diagnosis, monitoring, and management of many pediatric respiratory diseases as seen in the emergency room, intensive care, and outpatient settings. In this paper, the development and testing of a new noninvasive PF instrument, pneuRIPTM, which utilizes respiratory inductance plethysmography (RIP) are discussed. The pneuRIPTM hardware includes a small circuit board that connects to the RIP bands and measures and wirelessly transmits the band inductance data to any designated wirelessly connected tablet. The software provides indices of respiratory work presented instantaneously in a user-friendly graphical user interface on the tablet. The system was tested with ten normal children and compared with an existing system, Respitrace (Sensormedics, Yorba Linda, CA), under normal and loaded breathing conditions. Under normal breathing, the percentage differences between the two systems were 2.9% for labored breathing index (LBI), 31.8% for phase angle (Φ), 4.8% for percentage rib cage (RC%), and 26.7% for respiratory rate (BPM). Under loaded breathing, the percentage differences between the two systems were 1.6% for LBI, 4.1% for Φ, 8.5% for RC%, and 52.7% for BPM. For LBI, Φ, and RC%, the two systems were in general agreement. For BPM the pneuRIPTM is shown to be more accurate than the respitrace when compared to manually counting the breaths: 13.2% versus 36.4% accuracy for normal breathing and 16.9% versus 60.7% accuracy for breathing under load, respectively.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlepneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor
    typeJournal Paper
    journal volume11
    journal issue1
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4035546
    journal fristpage11010
    journal lastpage011010-6
    treeJournal of Medical Devices:;2017:;volume( 011 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian