    Sub-Beam Size Temperature Measurement of Heavily Doped Silicon Heater Using Two-Wavelength Thermoreflectance Microscopy

    Source: Journal of Heat Transfer:;2017:;volume( 139 ):;issue: 005::page 52703
    Author:
    Rho, Jinsung
    ,
    Jae Lee, Bong
    DOI: 10.1115/1.4035251
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This work describes a novel technique for simultaneously determining local temperature and thickness of a heavily doped Si heater having a submicron width by using two-wavelength thermoreflectance microscopy. The doped silicon line heater, whose thickness and width are, respectively, 480 nm and 900 nm, is fabricated by conventional microfabrication techniques on a fused silica wafer. The full width at half maximum (FWHM) of the focused laser beam is measured to be 2.00 μm and 2.28 μm for green (λ = 516 nm) and red (λ = 640 nm) lasers, respectively. Because the heater width is narrower than the focused laser beam size, the reflected beam contains background information (i.e., reflection from the fused silica substrate) in addition to the thermoreflectance signal from the doped silicon heater. With precise knowledge of the laser beam size, heater width, and exact location of the laser beam spot on the heater, one can quantitatively model the reflectance. In reality, however, due to the difficulty of aligning the laser beam with respect to the submicron-wide Si heater, precise determination of local temperature from thermoreflectance signal is not easily attained. In the present study, instead of aligning the laser beam to the center of the submicron silicon heater, the probe laser horizontally scans over a region of the heater. By taking into account the size of the focused laser beam and the width of the doped silicon heater, it is possible to determine the absolute temperature of a local region of the heater from the measured reflectance during the scanning, even though the width of the heater line is only 39% of the size of the laser beam.
    • Download: (2.485Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Sub-Beam Size Temperature Measurement of Heavily Doped Silicon Heater Using Two-Wavelength Thermoreflectance Microscopy

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4234431
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorRho, Jinsung
    contributor authorJae Lee, Bong
    date accessioned2017-11-25T07:17:11Z
    date available2017-11-25T07:17:11Z
    date copyright2017/7/2
    date issued2017
    identifier issn0022-1481
    identifier otherht_139_05_052703.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4234431
    description abstractThis work describes a novel technique for simultaneously determining local temperature and thickness of a heavily doped Si heater having a submicron width by using two-wavelength thermoreflectance microscopy. The doped silicon line heater, whose thickness and width are, respectively, 480 nm and 900 nm, is fabricated by conventional microfabrication techniques on a fused silica wafer. The full width at half maximum (FWHM) of the focused laser beam is measured to be 2.00 μm and 2.28 μm for green (λ = 516 nm) and red (λ = 640 nm) lasers, respectively. Because the heater width is narrower than the focused laser beam size, the reflected beam contains background information (i.e., reflection from the fused silica substrate) in addition to the thermoreflectance signal from the doped silicon heater. With precise knowledge of the laser beam size, heater width, and exact location of the laser beam spot on the heater, one can quantitatively model the reflectance. In reality, however, due to the difficulty of aligning the laser beam with respect to the submicron-wide Si heater, precise determination of local temperature from thermoreflectance signal is not easily attained. In the present study, instead of aligning the laser beam to the center of the submicron silicon heater, the probe laser horizontally scans over a region of the heater. By taking into account the size of the focused laser beam and the width of the doped silicon heater, it is possible to determine the absolute temperature of a local region of the heater from the measured reflectance during the scanning, even though the width of the heater line is only 39% of the size of the laser beam.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSub-Beam Size Temperature Measurement of Heavily Doped Silicon Heater Using Two-Wavelength Thermoreflectance Microscopy
    typeJournal Paper
    journal volume139
    journal issue5
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4035251
    journal fristpage52703
    journal lastpage052703-8
    treeJournal of Heat Transfer:;2017:;volume( 139 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian