Hydraulic Loss of Finite Length Dividing JunctionsSource: Journal of Fluids Engineering:;2017:;volume( 139 ):;issue: 003::page 31104DOI: 10.1115/1.4034876Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: A general hydraulic loss coefficient correlation for perpendicular, cylindrical, finite length dividing pipe junctions is developed and implemented in a discrete dividing-flow manifold model. Dividing-flow manifolds are used in several technical appliances, e.g., in water and wastewater treatment, swimming pool technology, air engineering, and polymer processing. Ensuring uniform flow distribution is a major goal of a flow manifold system design, whose accuracy is usually determined by the accuracies of applied flow coefficients. Coefficient of turning losses is calculated by a computational fluid dynamics (CFD)-based approach applying a nonlinear fit. In the case of a single-phase flow, the loss coefficient depends on four dimensionless parameters: the Reynolds number, the ratio of port and header flow velocities, the diameter ratio, and the ratio of the port length and the diameter of the pipe. Instead of experimentally covering this four-dimensional parameter space, more than 1000 judiciously chosen three-dimensional simulations were run to determine the loss coefficient for the parameter range most used in engineering practice. Validated results of our novel resistance formula show that the velocity and port length to header diameter ratios have a significant effect on the turning loss coefficient, while the diameter ratio and Reynolds number dependency are weaker in the investigated parameter ranges.
|
Collections
Show full item record
| contributor author | Tomor, András | |
| contributor author | Kristóf, Gergely | |
| date accessioned | 2017-11-25T07:16:22Z | |
| date available | 2017-11-25T07:16:22Z | |
| date copyright | 2017/19/1 | |
| date issued | 2017 | |
| identifier issn | 0098-2202 | |
| identifier other | fe_139_03_031104.pdf | |
| identifier uri | http://138.201.223.254:8080/yetl1/handle/yetl/4233971 | |
| description abstract | A general hydraulic loss coefficient correlation for perpendicular, cylindrical, finite length dividing pipe junctions is developed and implemented in a discrete dividing-flow manifold model. Dividing-flow manifolds are used in several technical appliances, e.g., in water and wastewater treatment, swimming pool technology, air engineering, and polymer processing. Ensuring uniform flow distribution is a major goal of a flow manifold system design, whose accuracy is usually determined by the accuracies of applied flow coefficients. Coefficient of turning losses is calculated by a computational fluid dynamics (CFD)-based approach applying a nonlinear fit. In the case of a single-phase flow, the loss coefficient depends on four dimensionless parameters: the Reynolds number, the ratio of port and header flow velocities, the diameter ratio, and the ratio of the port length and the diameter of the pipe. Instead of experimentally covering this four-dimensional parameter space, more than 1000 judiciously chosen three-dimensional simulations were run to determine the loss coefficient for the parameter range most used in engineering practice. Validated results of our novel resistance formula show that the velocity and port length to header diameter ratios have a significant effect on the turning loss coefficient, while the diameter ratio and Reynolds number dependency are weaker in the investigated parameter ranges. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Hydraulic Loss of Finite Length Dividing Junctions | |
| type | Journal Paper | |
| journal volume | 139 | |
| journal issue | 3 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.4034876 | |
| journal fristpage | 31104 | |
| journal lastpage | 031104-11 | |
| tree | Journal of Fluids Engineering:;2017:;volume( 139 ):;issue: 003 | |
| contenttype | Fulltext |