    Archive

    Including Housing–Casing Fluid in a Lateral Rotordynamics Analysis on Electric Submersible Pumps

    Source: Journal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 006::page 62505
    Author:
    Norrbin, Clay S.
    ,
    Childs, Dara W.
    ,
    Phillips, Stephen
    DOI: 10.1115/1.4035358
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Stability and synchronous-response predictions, which were presented by Childs et al. (2014, “A Lateral Rotordynamics Primer on Electric Submersible Pumps (ESPs) for Deep Subsea Applications,” 43th International Pump Users Symposium, Texas A&M University, College Station, TX, pp. 1–18), are re-evaluated to include the effect of the fluid between the pump housing and well casing. Conclusions are made based on these new findings. The same two-line rotor–housing model is used to model the pump's rotor and its housing. The model dimensions are based on direct measurements of an ESP. The pump rotor and pump housing are only connected together at each stage by reaction forces and moments from seals and bushings. The rotor model is pinned to the housing at the rotor's ends. The housing model is pinned to ground at its ends. Synchronous response predictions are presented for: (1) relative rotor–housing motion and (2) housing velocity-response amplitudes. When handling viscosity of water, the rotor–housing model is predicted to be stable at new (centered) 1× clearances but rapidly becomes unstable with enlarged clearances (2× and 3×), primarily due to rapidly dropping rotor–housing natural frequencies. The impact of introducing effective swirl brakes for the stages' wear ring seals was investigated for a pump running at 3600 rpm. Their predicted impact on stability and synchronous response was: (1) Onset speeds of instabilities (OSIs) were elevated well above running speed and (2) synchronous response amplitudes were reduced modestly. Housing-response amplitudes varied considerably with the choice of housing-termination locations. For a pump rotor length of Lr, varying the lengths of a centered housing over 1.5 Lr, 2 Lr, and 3 Lr changes the housing's natural frequency. This natural frequency can coincide with the running speed with proper termination conditions. If the running speed and natural frequency coincide, large housing vibration amplitudes associated with resonance would exceed most vibration regulations; however, relative rotor–stator response amplitudes were a small fraction of clearances for all the cases. When handling emulsions at markedly higher viscosities, with a pump speed of 3600 rpm and new centered clearances, the predicted OSI was below 300 rpm. The OSI rapidly increased as the seals were displaced eccentrically, quickly elevating the first rotor–stator natural frequency above 1800 rpm and the OSI above 3600 rpm. With the model stabilized at 0.2 eccentricity, the synchronous relative rotor–housing amplitudes were a small fraction of seal clearances. Swirl brakes were not predicted to be effective in elevating pump OSIs for high viscosity fluids with new clearances; however, they became effective as clearances were increased. An ESP housing can contact the well casing in many possible scenarios (axial locations, contact-area length or girth, etc.). A midspan, point radial contact was examined and modeled as a stiff-spring connection from the housing to ground. For both water and oil–water emulsions, a stiff housing-to-casing contact produced major elliptical housing motion (versus circular motion without contact). However, it had a comparably minor impact on relative rotor–housing response amplitudes or rotordynamic stability.
    • Download: (2.304Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Including Housing–Casing Fluid in a Lateral Rotordynamics Analysis on Electric Submersible Pumps

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4233717
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorNorrbin, Clay S.
    contributor authorChilds, Dara W.
    contributor authorPhillips, Stephen
    date accessioned2017-11-25T07:15:52Z
    date available2017-11-25T07:15:52Z
    date copyright2017/1/2
    date issued2017
    identifier issn0742-4795
    identifier othergtp_139_06_062505.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4233717
    description abstractStability and synchronous-response predictions, which were presented by Childs et al. (2014, “A Lateral Rotordynamics Primer on Electric Submersible Pumps (ESPs) for Deep Subsea Applications,” 43th International Pump Users Symposium, Texas A&M University, College Station, TX, pp. 1–18), are re-evaluated to include the effect of the fluid between the pump housing and well casing. Conclusions are made based on these new findings. The same two-line rotor–housing model is used to model the pump's rotor and its housing. The model dimensions are based on direct measurements of an ESP. The pump rotor and pump housing are only connected together at each stage by reaction forces and moments from seals and bushings. The rotor model is pinned to the housing at the rotor's ends. The housing model is pinned to ground at its ends. Synchronous response predictions are presented for: (1) relative rotor–housing motion and (2) housing velocity-response amplitudes. When handling viscosity of water, the rotor–housing model is predicted to be stable at new (centered) 1× clearances but rapidly becomes unstable with enlarged clearances (2× and 3×), primarily due to rapidly dropping rotor–housing natural frequencies. The impact of introducing effective swirl brakes for the stages' wear ring seals was investigated for a pump running at 3600 rpm. Their predicted impact on stability and synchronous response was: (1) Onset speeds of instabilities (OSIs) were elevated well above running speed and (2) synchronous response amplitudes were reduced modestly. Housing-response amplitudes varied considerably with the choice of housing-termination locations. For a pump rotor length of Lr, varying the lengths of a centered housing over 1.5 Lr, 2 Lr, and 3 Lr changes the housing's natural frequency. This natural frequency can coincide with the running speed with proper termination conditions. If the running speed and natural frequency coincide, large housing vibration amplitudes associated with resonance would exceed most vibration regulations; however, relative rotor–stator response amplitudes were a small fraction of clearances for all the cases. When handling emulsions at markedly higher viscosities, with a pump speed of 3600 rpm and new centered clearances, the predicted OSI was below 300 rpm. The OSI rapidly increased as the seals were displaced eccentrically, quickly elevating the first rotor–stator natural frequency above 1800 rpm and the OSI above 3600 rpm. With the model stabilized at 0.2 eccentricity, the synchronous relative rotor–housing amplitudes were a small fraction of seal clearances. Swirl brakes were not predicted to be effective in elevating pump OSIs for high viscosity fluids with new clearances; however, they became effective as clearances were increased. An ESP housing can contact the well casing in many possible scenarios (axial locations, contact-area length or girth, etc.). A midspan, point radial contact was examined and modeled as a stiff-spring connection from the housing to ground. For both water and oil–water emulsions, a stiff housing-to-casing contact produced major elliptical housing motion (versus circular motion without contact). However, it had a comparably minor impact on relative rotor–housing response amplitudes or rotordynamic stability.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleIncluding Housing–Casing Fluid in a Lateral Rotordynamics Analysis on Electric Submersible Pumps
    typeJournal Paper
    journal volume139
    journal issue6
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4035358
    journal fristpage62505
    journal lastpage062505-12
    treeJournal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian