The Design and Performance of a 6-Cup AnemometerSource: Journal of Applied Meteorology:;1975:;volume( 014 ):;issue: 006::page 1135Author:Lindley, D.
DOI: 10.1175/1520-0450(1975)014<1135:TDAPOA>2.0.CO;2Publisher: American Meteorological Society
Abstract: An investigation is made into the design and performance of ?staggered? 6-cup anemometers. It is found that the optimum cup arm radius to cup radius ratio (R/r) for both these and 3-cup anemometers is indeterminate; the value to be used in any design only depends on the speed of cup rotation required for a given wind speed. The calibrations for such instruments were linear at all settings of R/r. Distance constants as low as 0.5 m were obtained at an optimum setting of cup wheel spacing to cup radius (L/r) of 2.5 for wheels of all polystyrene construction. Tests of 6-cup, 3-cup and propeller anemometers in a sinusoidally fluctuating air stream demonstrated that the percentage overestimation of the mean wind speed varied from 3% (for the Gill 4-blade propeller) to 11.5% for the 3-cup (lipless) anemometer of all polystyrene construction at a gust amplitude of 0.5. The 6-cup anemometer had a marked superiority in these tests over the 3-cup anemometers and also had lower starting speeds.
|
Collections
Show full item record
| contributor author | Lindley, D. | |
| date accessioned | 2017-06-09T17:38:19Z | |
| date available | 2017-06-09T17:38:19Z | |
| date copyright | 1975/09/01 | |
| date issued | 1975 | |
| identifier issn | 0021-8952 | |
| identifier other | ams-8943.pdf | |
| identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4232376 | |
| description abstract | An investigation is made into the design and performance of ?staggered? 6-cup anemometers. It is found that the optimum cup arm radius to cup radius ratio (R/r) for both these and 3-cup anemometers is indeterminate; the value to be used in any design only depends on the speed of cup rotation required for a given wind speed. The calibrations for such instruments were linear at all settings of R/r. Distance constants as low as 0.5 m were obtained at an optimum setting of cup wheel spacing to cup radius (L/r) of 2.5 for wheels of all polystyrene construction. Tests of 6-cup, 3-cup and propeller anemometers in a sinusoidally fluctuating air stream demonstrated that the percentage overestimation of the mean wind speed varied from 3% (for the Gill 4-blade propeller) to 11.5% for the 3-cup (lipless) anemometer of all polystyrene construction at a gust amplitude of 0.5. The 6-cup anemometer had a marked superiority in these tests over the 3-cup anemometers and also had lower starting speeds. | |
| publisher | American Meteorological Society | |
| title | The Design and Performance of a 6-Cup Anemometer | |
| type | Journal Paper | |
| journal volume | 14 | |
| journal issue | 6 | |
| journal title | Journal of Applied Meteorology | |
| identifier doi | 10.1175/1520-0450(1975)014<1135:TDAPOA>2.0.CO;2 | |
| journal fristpage | 1135 | |
| journal lastpage | 1145 | |
| tree | Journal of Applied Meteorology:;1975:;volume( 014 ):;issue: 006 | |
| contenttype | Fulltext |