    Discriminating Environmental Conditions for Significant Warm Sector and Boundary Tornadoes in Parts of the Great Plains

    Source: Weather and Forecasting:;2013:;volume( 028 ):;issue: 006::page 1498
    Author:
    Boustead, Joshua M.
    ,
    Mayes, Barbara E.
    ,
    Gargan, William
    ,
    Leighton, Jared L.
    ,
    Phillips, George
    ,
    Schumacher, Philip N.
    DOI: 10.1175/WAF-D-12-00102.1
    Publisher: American Meteorological Society
    Abstract: sing system-relative composites, based on a dataset of significant tornadoes and null supercell events, environmental conditions associated with occurrences of significant tornadoes near discernible surface boundaries were compared to nontornadic boundary supercells, and warm sector significant tornadoes to nontornadic warm sector supercells, for a portion of the Great Plains. Results indicated that significant boundary tornadoes were associated with the exit region of a 300-hPa jet maximum, while null boundary events were in closer proximity to the 300-hPa jet entrance region. The differences at 300 hPa led to significant differences at the surface, as the null composite indicated deformation and confluence into the surface boundary and enhanced frontogenesis, while this was not present in the boundary significant tornado composite. Significant synoptic differences also were noted between the warm sector tornadoes and the warm sector null events. The warm sector significant tornadoes were associated with a much stronger, negatively tilted synoptic storm system, with the composite tornado in the 300-hPa jet exit region and downstream of increasing values of absolute vorticity. Additional thermodynamic and kinematic parameters pertaining to low-level moisture and environmental winds appeared to be important in distinguishing boundary and warm sector significant tornadoes from nontornadic supercell events. Statistical comparisons between boundary and warm sector significant tornado events showed significant differences in the climatology of their length, width, and date and time of occurrence.
    • Download: (4.596Mb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Statistics

      Discriminating Environmental Conditions for Significant Warm Sector and Boundary Tornadoes in Parts of the Great Plains

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4231619
    Collections
    • Weather and Forecasting

    Show full item record

    contributor authorBoustead, Joshua M.
    contributor authorMayes, Barbara E.
    contributor authorGargan, William
    contributor authorLeighton, Jared L.
    contributor authorPhillips, George
    contributor authorSchumacher, Philip N.
    date accessioned2017-06-09T17:36:10Z
    date available2017-06-09T17:36:10Z
    date copyright2013/12/01
    date issued2013
    identifier issn0882-8156
    identifier otherams-87900.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4231619
    description abstractsing system-relative composites, based on a dataset of significant tornadoes and null supercell events, environmental conditions associated with occurrences of significant tornadoes near discernible surface boundaries were compared to nontornadic boundary supercells, and warm sector significant tornadoes to nontornadic warm sector supercells, for a portion of the Great Plains. Results indicated that significant boundary tornadoes were associated with the exit region of a 300-hPa jet maximum, while null boundary events were in closer proximity to the 300-hPa jet entrance region. The differences at 300 hPa led to significant differences at the surface, as the null composite indicated deformation and confluence into the surface boundary and enhanced frontogenesis, while this was not present in the boundary significant tornado composite. Significant synoptic differences also were noted between the warm sector tornadoes and the warm sector null events. The warm sector significant tornadoes were associated with a much stronger, negatively tilted synoptic storm system, with the composite tornado in the 300-hPa jet exit region and downstream of increasing values of absolute vorticity. Additional thermodynamic and kinematic parameters pertaining to low-level moisture and environmental winds appeared to be important in distinguishing boundary and warm sector significant tornadoes from nontornadic supercell events. Statistical comparisons between boundary and warm sector significant tornado events showed significant differences in the climatology of their length, width, and date and time of occurrence.
    publisherAmerican Meteorological Society
    titleDiscriminating Environmental Conditions for Significant Warm Sector and Boundary Tornadoes in Parts of the Great Plains
    typeJournal Paper
    journal volume28
    journal issue6
    journal titleWeather and Forecasting
    identifier doi10.1175/WAF-D-12-00102.1
    journal fristpage1498
    journal lastpage1523
    treeWeather and Forecasting:;2013:;volume( 028 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian