    Digital Output Wind System for Airport Use

    Source: Journal of Applied Meteorology:;1973:;volume( 012 ):;issue: 003::page 529
    Author:
    Koren, Oscar
    DOI: 10.1175/1520-0450(1973)012<0529:DOWSFA>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: The workload in Air Traffic Control Centers often prohibits the controllers from making lengthy observations of the moving pointer indicators in order to obtain sufficiently representative estimates of the current surface wind. A requirement for wind instruments permitting read-out of the current wind information in digital form has been advanced by the International Civil Aviation Organization. Consequently, a project was initiated at the Instrument Division, Atmospheric Environment Service, to develop a wind system capable of providing representative estimates of the current wind automatically. In this paper the present status of the above-mentioned project is discussed. The system developed to date consists of a standard Atmospheric Environment Service 3-cup anemometer and wind vane, a signal processing unit, and a digital display panel. The wind speed and direction information is displayed to the observer in the form of a one-sided 2-min running mean, while the gustiness is indicated by the peak gust in the last 10 min, decayed at a rate of 1 mph min?1. A high-speed Hewlett-Packard 2010 series data logger was used to evaluate the system. The analog signal from the cup anemometer was recorded by the data logger directly, and also through the signal processing unit. Similarly, the wind direction signal from the vane-driven Muirhead 18M4J1 synchro motor was recorded by the data logger through a low-torque Baldwin 80 Series optical encoder and also through the signal processing unit. Thus, simultaneous records of the processed and unprocessed wind signals were obtained for further analysis. These records were then read into a PDP-10/50 computer and direct comparisons were made between the computed one-sided running means and those given by the wind processing unit. The analysis showed that the root-mean-square difference between the computed and the indicated mean wind speeds was 0.3 mph. The data provided by the wind system were compared with those data satisfying the standard airport wind algorithm. According to this algorithm the airport wind speed and direction are given as 2-min running means, while for the gustiness value the peak gust in the preceding 10 min is indicated. It was found that the largest difference between the wind information supplied by the wind system and that specified by the algorithm was less than 10°, 2 mph and 4 mph, respectively, for direction, speed and gustiness. The chief advantage of the system is that it is relatively inexpensive and that it possesses typical analog accuracy, which is more than adequate for aeronautical applications. Furthermore, by using simple logic circuits no special consideration has to be given to the 360° crossover when averaging the wind direction. The system is intended primarily for airport use; however, it also holds considerable promise as a sensor for automatic weather stations.
    • Download: (493.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Statistics

      Digital Output Wind System for Airport Use

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4228867
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorKoren, Oscar
    date accessioned2017-06-09T17:26:45Z
    date available2017-06-09T17:26:45Z
    date copyright1973/04/01
    date issued1973
    identifier issn0021-8952
    identifier otherams-8542.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4228867
    description abstractThe workload in Air Traffic Control Centers often prohibits the controllers from making lengthy observations of the moving pointer indicators in order to obtain sufficiently representative estimates of the current surface wind. A requirement for wind instruments permitting read-out of the current wind information in digital form has been advanced by the International Civil Aviation Organization. Consequently, a project was initiated at the Instrument Division, Atmospheric Environment Service, to develop a wind system capable of providing representative estimates of the current wind automatically. In this paper the present status of the above-mentioned project is discussed. The system developed to date consists of a standard Atmospheric Environment Service 3-cup anemometer and wind vane, a signal processing unit, and a digital display panel. The wind speed and direction information is displayed to the observer in the form of a one-sided 2-min running mean, while the gustiness is indicated by the peak gust in the last 10 min, decayed at a rate of 1 mph min?1. A high-speed Hewlett-Packard 2010 series data logger was used to evaluate the system. The analog signal from the cup anemometer was recorded by the data logger directly, and also through the signal processing unit. Similarly, the wind direction signal from the vane-driven Muirhead 18M4J1 synchro motor was recorded by the data logger through a low-torque Baldwin 80 Series optical encoder and also through the signal processing unit. Thus, simultaneous records of the processed and unprocessed wind signals were obtained for further analysis. These records were then read into a PDP-10/50 computer and direct comparisons were made between the computed one-sided running means and those given by the wind processing unit. The analysis showed that the root-mean-square difference between the computed and the indicated mean wind speeds was 0.3 mph. The data provided by the wind system were compared with those data satisfying the standard airport wind algorithm. According to this algorithm the airport wind speed and direction are given as 2-min running means, while for the gustiness value the peak gust in the preceding 10 min is indicated. It was found that the largest difference between the wind information supplied by the wind system and that specified by the algorithm was less than 10°, 2 mph and 4 mph, respectively, for direction, speed and gustiness. The chief advantage of the system is that it is relatively inexpensive and that it possesses typical analog accuracy, which is more than adequate for aeronautical applications. Furthermore, by using simple logic circuits no special consideration has to be given to the 360° crossover when averaging the wind direction. The system is intended primarily for airport use; however, it also holds considerable promise as a sensor for automatic weather stations.
    publisherAmerican Meteorological Society
    titleDigital Output Wind System for Airport Use
    typeJournal Paper
    journal volume12
    journal issue3
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1973)012<0529:DOWSFA>2.0.CO;2
    journal fristpage529
    journal lastpage536
    treeJournal of Applied Meteorology:;1973:;volume( 012 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian