    Cold Air Drainage on a Forested Mountain Slope

    Source: Journal of Applied Meteorology:;1969:;volume( 008 ):;issue: 006::page 884
    Author:
    Bergen, James D.
    DOI: 10.1175/1520-0450(1969)008<0884:CADOAF>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: The nocturnal cold airflow on a small forested slope was studied in an attempt to relate the volume and velocity of flow to the net radiation balance of the slope. The hillside, with an approximately 30% grade, was about 400 m long and covered with an uneven-aged spruce-fir stand of about 20 m height. The location was near Fraser, Colo., at an altitude of 3000 m. The vertical profiles of wind speed and air temperature were measured at various points on a transect approximating a streamline segment down the hill for several nights. Net radiation was measured at the base of the transect. Canopy closure and tree heights and diameters were measured on sample plots along the transect. The vertical profiles of potential temperature deficit and wind speed at the various stations show approximate similarity when scaled by the height of the lowest inversion and by the average velocities and potential temperature deficits below that inversion. The latter varies in a nearly linear manner down the slope, and the inversion heights appear to be relatively constant over the range of net radiation rates observed. Assuming a corresponding analytical similarity for the equations of motion and the sensible heat balance, the last two phenomena are found to imply that Um???, ???R0?, Um/??x, where Um is the average velocity indicated above, ?? the potential temperature drop down the slope, ? the sine of the angle of the slope to the horizontal along the streamline, x the downslope distance from the virtual origin of the flow measured along the streamline, and R0 the average net radiation loss on the slope. The data appear to confirm these results. The constants of proportionality calculated from the topographic contours, the estimated foliage distribution, and the scaled profiles of wind speed and potential temperature deficit are in fair agreement with observations.
    • Download: (844.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Statistics

      Cold Air Drainage on a Forested Mountain Slope

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4221900
    Collections
    • Journal of Applied Meteorology

    Show full item record

    contributor authorBergen, James D.
    date accessioned2017-06-09T17:05:08Z
    date available2017-06-09T17:05:08Z
    date copyright1969/12/01
    date issued1969
    identifier issn0021-8952
    identifier otherams-7915.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4221900
    description abstractThe nocturnal cold airflow on a small forested slope was studied in an attempt to relate the volume and velocity of flow to the net radiation balance of the slope. The hillside, with an approximately 30% grade, was about 400 m long and covered with an uneven-aged spruce-fir stand of about 20 m height. The location was near Fraser, Colo., at an altitude of 3000 m. The vertical profiles of wind speed and air temperature were measured at various points on a transect approximating a streamline segment down the hill for several nights. Net radiation was measured at the base of the transect. Canopy closure and tree heights and diameters were measured on sample plots along the transect. The vertical profiles of potential temperature deficit and wind speed at the various stations show approximate similarity when scaled by the height of the lowest inversion and by the average velocities and potential temperature deficits below that inversion. The latter varies in a nearly linear manner down the slope, and the inversion heights appear to be relatively constant over the range of net radiation rates observed. Assuming a corresponding analytical similarity for the equations of motion and the sensible heat balance, the last two phenomena are found to imply that Um???, ???R0?, Um/??x, where Um is the average velocity indicated above, ?? the potential temperature drop down the slope, ? the sine of the angle of the slope to the horizontal along the streamline, x the downslope distance from the virtual origin of the flow measured along the streamline, and R0 the average net radiation loss on the slope. The data appear to confirm these results. The constants of proportionality calculated from the topographic contours, the estimated foliage distribution, and the scaled profiles of wind speed and potential temperature deficit are in fair agreement with observations.
    publisherAmerican Meteorological Society
    titleCold Air Drainage on a Forested Mountain Slope
    typeJournal Paper
    journal volume8
    journal issue6
    journal titleJournal of Applied Meteorology
    identifier doi10.1175/1520-0450(1969)008<0884:CADOAF>2.0.CO;2
    journal fristpage884
    journal lastpage895
    treeJournal of Applied Meteorology:;1969:;volume( 008 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian