| description abstract | An extensive series of experiments was carried out to compare the performance of two cloud nucleus counters, a Static Diffusion Chamber and a Thermal Diffusion Tube, operating under quite different principles, in a wide range of field conditions and with a number of laboratory aerosols. The operating ranges of the instruments only overlap slightly; nevertheless the supersaturation vs cloud condensation nuclei (CCN) concentration spectra obtained showed rather good agreement at the range boundaries and suggest that use of the two instruments would provide a viable method of obtaining CCN concentrations in the supersaturation range 0.04 to 1.25 percent. | |
| publisher | American Meteorological Society | |
| title | Field and Laboratory Comparisons of Two Cloud Condensation Nuclei Counters | |
| type | Journal Paper | |
| journal volume | 6 | |
| journal issue | 6 | |
| journal title | Journal of Atmospheric and Oceanic Technology | |
| identifier doi | 10.1175/1520-0426(1989)006<1066:FALCOT>2.0.CO;2 | |
| journal fristpage | 1066 | |
| journal lastpage | 1078 | |
| tree | Journal of Atmospheric and Oceanic Technology:;1989:;volume( 006 ):;issue: 006 | |
| contenttype | Fulltext | |