YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • AMS
    • Bulletin of the American Meteorological Society
    • View Item
    •   YE&T Library
    • AMS
    • Bulletin of the American Meteorological Society
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    The USDA Ultraviolet Radiation Monitoring Program

    Source: Bulletin of the American Meteorological Society:;1998:;volume( 079 ):;issue: 004::page 601
    Author:
    Bigelow, D. S.
    ,
    Slusser, J. R.
    ,
    Beaubien, A. F.
    ,
    Gibson, J. H.
    DOI: 10.1175/1520-0477(1998)079<0601:TUURMP>2.0.CO;2
    Publisher: American Meteorological Society
    Abstract: The U.S. Department of Agriculture's Ultraviolet (UV) Radiation Monitoring Program has been measuring UV radiation since 1994. The initial network of 12 stations employed broadband meters to measure UVB irradiance and included ancillary measurements of temperature, humidity, and irradiance at seven wavelengths in the visible produced by a Multi-Filter Rotating Shadowband Radiometer (MFRSR). Since that beginning the network has expanded to more than 20 stations and the broadband meters have been supplemented with a seven-wavelength Ultraviolet Multi-Filter Rotating Shadowband Radiometer (UV-MFRSR). The network has been designed to include 30 stations, each with a full complement of instrumentation. Annual characterizations of the network's filter radiometers indicate that gradual shifts in instrument response are manageable but must be accounted for to achieve accurate and precise measurements of UV irradiance. The characterization and calibration of the filter instruments is discussed along with filter stability and instrument precision. Broadband instruments are shown to be quite stable and collocated instruments are shown to agree to within 2.3% for zenith angles less than 80° under all sky conditions. Preliminary investigations into the accuracy of the UV-MFRSR calibrated with the Langley method are presented and successful column ozone retrievals are demonstrated with the UV-MFRSR under clear skies.
    • Download: (302.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Item Order
    • Go To Publisher
    • Statistics

      The USDA Ultraviolet Radiation Monitoring Program

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4161508
    Collections
    • Bulletin of the American Meteorological Society

    Show full item record

    contributor authorBigelow, D. S.
    contributor authorSlusser, J. R.
    contributor authorBeaubien, A. F.
    contributor authorGibson, J. H.
    date accessioned2017-06-09T14:42:06Z
    date available2017-06-09T14:42:06Z
    date copyright1998/04/01
    date issued1998
    identifier issn0003-0007
    identifier otherams-24797.pdf
    identifier urihttp://onlinelibrary.yabesh.ir/handle/yetl/4161508
    description abstractThe U.S. Department of Agriculture's Ultraviolet (UV) Radiation Monitoring Program has been measuring UV radiation since 1994. The initial network of 12 stations employed broadband meters to measure UVB irradiance and included ancillary measurements of temperature, humidity, and irradiance at seven wavelengths in the visible produced by a Multi-Filter Rotating Shadowband Radiometer (MFRSR). Since that beginning the network has expanded to more than 20 stations and the broadband meters have been supplemented with a seven-wavelength Ultraviolet Multi-Filter Rotating Shadowband Radiometer (UV-MFRSR). The network has been designed to include 30 stations, each with a full complement of instrumentation. Annual characterizations of the network's filter radiometers indicate that gradual shifts in instrument response are manageable but must be accounted for to achieve accurate and precise measurements of UV irradiance. The characterization and calibration of the filter instruments is discussed along with filter stability and instrument precision. Broadband instruments are shown to be quite stable and collocated instruments are shown to agree to within 2.3% for zenith angles less than 80° under all sky conditions. Preliminary investigations into the accuracy of the UV-MFRSR calibrated with the Langley method are presented and successful column ozone retrievals are demonstrated with the UV-MFRSR under clear skies.
    publisherAmerican Meteorological Society
    titleThe USDA Ultraviolet Radiation Monitoring Program
    typeJournal Paper
    journal volume79
    journal issue4
    journal titleBulletin of the American Meteorological Society
    identifier doi10.1175/1520-0477(1998)079<0601:TUURMP>2.0.CO;2
    journal fristpage601
    journal lastpage615
    treeBulletin of the American Meteorological Society:;1998:;volume( 079 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian