On the Temperature Correction of the Aquatrak Acoustic Tide GaugeSource: Journal of Atmospheric and Oceanic Technology:;2003:;volume( 020 ):;issue: 008::page 1230Author:Hunter, John R.
DOI: 10.1175/1520-0426(2003)020<1230:OTTCOT>2.0.CO;2Publisher: American Meteorological Society
Abstract: Temperature corrections for the Aquatrak acoustic tide gauge are derived. These account for variable temperature (and hence sound velocity) along the sounding tube, thermal expansion of the calibration tube, and the thermal response of the transducer/controller combination. When averaged over long periods (e.g., seasonal), the corrections are typically several millimeters in magnitude, with short-period (e.g., diurnal) variations as large as several centimeters. The correction associated with thermal expansion of the calibration tube is of the same order as the correction for variable sound velocity, which is already applied at some Aquatrak installations. The corrections derived here relate to the situation in which an initial adjustment has been made by the manufacturer (making the calibration tube a fixed known length under factory conditions), and a subsequent calibration is performed to define a single zero offset for the instrument.
|
Collections
Show full item record
| contributor author | Hunter, John R. | |
| date accessioned | 2017-06-09T14:33:30Z | |
| date available | 2017-06-09T14:33:30Z | |
| date copyright | 2003/08/01 | |
| date issued | 2003 | |
| identifier issn | 0739-0572 | |
| identifier other | ams-2162.pdf | |
| identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4157979 | |
| description abstract | Temperature corrections for the Aquatrak acoustic tide gauge are derived. These account for variable temperature (and hence sound velocity) along the sounding tube, thermal expansion of the calibration tube, and the thermal response of the transducer/controller combination. When averaged over long periods (e.g., seasonal), the corrections are typically several millimeters in magnitude, with short-period (e.g., diurnal) variations as large as several centimeters. The correction associated with thermal expansion of the calibration tube is of the same order as the correction for variable sound velocity, which is already applied at some Aquatrak installations. The corrections derived here relate to the situation in which an initial adjustment has been made by the manufacturer (making the calibration tube a fixed known length under factory conditions), and a subsequent calibration is performed to define a single zero offset for the instrument. | |
| publisher | American Meteorological Society | |
| title | On the Temperature Correction of the Aquatrak Acoustic Tide Gauge | |
| type | Journal Paper | |
| journal volume | 20 | |
| journal issue | 8 | |
| journal title | Journal of Atmospheric and Oceanic Technology | |
| identifier doi | 10.1175/1520-0426(2003)020<1230:OTTCOT>2.0.CO;2 | |
| journal fristpage | 1230 | |
| journal lastpage | 1235 | |
| tree | Journal of Atmospheric and Oceanic Technology:;2003:;volume( 020 ):;issue: 008 | |
| contenttype | Fulltext |