Anemometry in Icing ConditionsSource: Journal of Atmospheric and Oceanic Technology:;2001:;volume( 018 ):;issue: 009::page 1457DOI: 10.1175/1520-0426(2001)018<1457:AIIC>2.0.CO;2Publisher: American Meteorological Society
Abstract: The accuracy of wind measurements in icing conditions is discussed, and wind tunnel calibrations as well as field comparisons are presented for three heated anemometers that use different measuring principles. It is pointed out that ice-free anemometer calibrations, including those provided by manufacturers, are affected by the blockage effect in wind tunnels that are too small. Some anemometers that measure correctly in a wind tunnel give erroneous results in the field. Overall, measuring mean wind speeds and peak values in icing conditions with the accuracy of about 5% seems possible with the present technology, both with rotational and sonic anemometers, but in the most severe environments only some internally heated rotational anemometers are reliable. Wind measurements in icing conditions without due consideration of anemometer selection, specific instrument problems, calibration inaccuracies, mean vertical velocity component, and anti-icing of the supporting structures may result in very big errors.
|
Collections
Show full item record
| contributor author | Makkonen, Lasse | |
| contributor author | Lehtonen, Pertti | |
| contributor author | Helle, Lauri | |
| date accessioned | 2017-06-09T14:25:33Z | |
| date available | 2017-06-09T14:25:33Z | |
| date copyright | 2001/09/01 | |
| date issued | 2001 | |
| identifier issn | 0739-0572 | |
| identifier other | ams-1902.pdf | |
| identifier uri | http://onlinelibrary.yabesh.ir/handle/yetl/4155090 | |
| description abstract | The accuracy of wind measurements in icing conditions is discussed, and wind tunnel calibrations as well as field comparisons are presented for three heated anemometers that use different measuring principles. It is pointed out that ice-free anemometer calibrations, including those provided by manufacturers, are affected by the blockage effect in wind tunnels that are too small. Some anemometers that measure correctly in a wind tunnel give erroneous results in the field. Overall, measuring mean wind speeds and peak values in icing conditions with the accuracy of about 5% seems possible with the present technology, both with rotational and sonic anemometers, but in the most severe environments only some internally heated rotational anemometers are reliable. Wind measurements in icing conditions without due consideration of anemometer selection, specific instrument problems, calibration inaccuracies, mean vertical velocity component, and anti-icing of the supporting structures may result in very big errors. | |
| publisher | American Meteorological Society | |
| title | Anemometry in Icing Conditions | |
| type | Journal Paper | |
| journal volume | 18 | |
| journal issue | 9 | |
| journal title | Journal of Atmospheric and Oceanic Technology | |
| identifier doi | 10.1175/1520-0426(2001)018<1457:AIIC>2.0.CO;2 | |
| journal fristpage | 1457 | |
| journal lastpage | 1469 | |
| tree | Journal of Atmospheric and Oceanic Technology:;2001:;volume( 018 ):;issue: 009 | |
| contenttype | Fulltext |