description abstractA high-performance liquid chromatographic analytical technique has been developed for the separation of hydrogen peroxide and low molecular weight organic hydroperoxides. A total of 10 C1?C3 organic hydroperoxides have been separated. The detection system is based on postcolumn derivatization using an enzymatic reaction with p-hydroxyphenylacelic acid to form a fluorescent dimer. The detection limit for the technique is 9 ? 10?8 M for hydrogen peroxide and 2 ? 10?8 M for other hydroperoxides. This paper details the optimization of the analytical technique, examining column characteristics and the chemistry of the analytical reaction.
publisherAmerican Meteorological Society
titleHPLC Determination of Atmospheric Organic Hydroperoxides
typeJournal Paper
journal volume12
journal issue2
journal titleJournal of Atmospheric and Oceanic Technology
identifier doi10.1175/1520-0426(1995)012<0282:HDOAOH>2.0.CO;2
journal fristpage282
journal lastpage289
treeJournal of Atmospheric and Oceanic Technology:;1995:;volume( 012 ):;issue: 002