    Archive

    Pulsation Errors in Compressible Flow Measurement

    Source: Journal of Environmental Engineering:;1993:;Volume ( 119 ):;issue: 002
    Author:
    Tamar Stephens
    ,
    Mark A. Tumeo
    DOI: 10.1061/(ASCE)0733-9372(1993)119:2(384)
    Publisher: American Society of Civil Engineers
    Abstract: As part of a study of the effects of varying aeration patterns and diffuser types on an extended aeration wastewater treatment system, researchers employed float-type rotameters with a range of 0-80 L/min (0-2.9 cfm) operating between 0 to 138 kPa (0-20 psi). During operation of the system, it was discovered that readings on the influent air meter and internal flow meters showed a consistent discrepancy of over 16 L/min (30% loss). This error did not occur when the air system was run without water in the tank. The simple structure and basic principle of operation should have made the flowmeters reliable and easy to work with. This discrepancy led the researchers to investigate several possible problems, including leaks, defects in the flowmeters and pressure, and temperature effects and pulsation. It was determined that pulsation from the compressor was the source of the discrepancy. Flow measurement errors in the system were corrected by installing a small, inexpensive accumulator.
    • Download: (285.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Pulsation Errors in Compressible Flow Measurement

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/41052
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorTamar Stephens
    contributor authorMark A. Tumeo
    date accessioned2017-05-08T21:09:47Z
    date available2017-05-08T21:09:47Z
    date copyrightMarch 1993
    date issued1993
    identifier other%28asce%290733-9372%281993%29119%3A2%28384%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/41052
    description abstractAs part of a study of the effects of varying aeration patterns and diffuser types on an extended aeration wastewater treatment system, researchers employed float-type rotameters with a range of 0-80 L/min (0-2.9 cfm) operating between 0 to 138 kPa (0-20 psi). During operation of the system, it was discovered that readings on the influent air meter and internal flow meters showed a consistent discrepancy of over 16 L/min (30% loss). This error did not occur when the air system was run without water in the tank. The simple structure and basic principle of operation should have made the flowmeters reliable and easy to work with. This discrepancy led the researchers to investigate several possible problems, including leaks, defects in the flowmeters and pressure, and temperature effects and pulsation. It was determined that pulsation from the compressor was the source of the discrepancy. Flow measurement errors in the system were corrected by installing a small, inexpensive accumulator.
    publisherAmerican Society of Civil Engineers
    titlePulsation Errors in Compressible Flow Measurement
    typeJournal Paper
    journal volume119
    journal issue2
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(1993)119:2(384)
    treeJournal of Environmental Engineering:;1993:;Volume ( 119 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian