YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Water Resources Planning and Management
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Water Quality Model Calibration under Unknown Demands

    Source: Journal of Water Resources Planning and Management:;2008:;Volume ( 134 ):;issue: 004
    Author:
    P. M. Jonkergouw
    ,
    S.-T. Khu
    ,
    Z. S. Kapelan
    ,
    D. A. Savić
    DOI: 10.1061/(ASCE)0733-9496(2008)134:4(326)
    Publisher: American Society of Civil Engineers
    Abstract: It has often been cited that a water distribution system (WDS) hydraulic model needs to be highly accurate before it may be used in combination with a water quality model (WQM) to simulate the dispersion and decay of a residual disinfectant. However, even a well-calibrated WDS hydraulic model may not have data relating to the specific water demands during a given period, which may impede WQM calibration. This study examines using residual disinfectant data to calibrate a WQM under unknown or uncertain demands by calibrating a residential demand multiplier pattern (DMP) in tandem with the WQM parameters. Two artificial scenarios and one real case study are investigated. The artificial scenarios are used to (1) verify the proposed methodology under ideal conditions and (2) validate the proposed methodology when the hydraulic model and calibration data contain realistic errors. The real case study uses residual chlorine data and a WDS model for which a hydraulic and WQM calibration had been performed previously. The estimated demands from the real case study are validated using tracer test data. Results from the artificial case studies may be summarized as follows: (1) the proposed methodology can estimate the demands and calibrate WQM parameters correctly, although increasing model and calibration data errors adversely affect calibration results; (2) the calibrated WDS models reproduce the true residual chlorine concentrations with very little error. Results from the real case study indicate that the original WQM calibration was performed using underestimated WDS demands. Tracer test data confirm that the calibrated DMP provides good hydraulic velocities. The calibrated WDS model from the real case study is in good agreement with measured residual chlorine concentrations. The mean absolute error between the simulated chlorine concentrations from the calibrated network model and the observed values is
    • Download: (671.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Water Quality Model Calibration under Unknown Demands

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/40162
    Collections
    • Journal of Water Resources Planning and Management

    Show full item record

    contributor authorP. M. Jonkergouw
    contributor authorS.-T. Khu
    contributor authorZ. S. Kapelan
    contributor authorD. A. Savić
    date accessioned2017-05-08T21:08:22Z
    date available2017-05-08T21:08:22Z
    date copyrightJuly 2008
    date issued2008
    identifier other%28asce%290733-9496%282008%29134%3A4%28326%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/40162
    description abstractIt has often been cited that a water distribution system (WDS) hydraulic model needs to be highly accurate before it may be used in combination with a water quality model (WQM) to simulate the dispersion and decay of a residual disinfectant. However, even a well-calibrated WDS hydraulic model may not have data relating to the specific water demands during a given period, which may impede WQM calibration. This study examines using residual disinfectant data to calibrate a WQM under unknown or uncertain demands by calibrating a residential demand multiplier pattern (DMP) in tandem with the WQM parameters. Two artificial scenarios and one real case study are investigated. The artificial scenarios are used to (1) verify the proposed methodology under ideal conditions and (2) validate the proposed methodology when the hydraulic model and calibration data contain realistic errors. The real case study uses residual chlorine data and a WDS model for which a hydraulic and WQM calibration had been performed previously. The estimated demands from the real case study are validated using tracer test data. Results from the artificial case studies may be summarized as follows: (1) the proposed methodology can estimate the demands and calibrate WQM parameters correctly, although increasing model and calibration data errors adversely affect calibration results; (2) the calibrated WDS models reproduce the true residual chlorine concentrations with very little error. Results from the real case study indicate that the original WQM calibration was performed using underestimated WDS demands. Tracer test data confirm that the calibrated DMP provides good hydraulic velocities. The calibrated WDS model from the real case study is in good agreement with measured residual chlorine concentrations. The mean absolute error between the simulated chlorine concentrations from the calibrated network model and the observed values is
    publisherAmerican Society of Civil Engineers
    titleWater Quality Model Calibration under Unknown Demands
    typeJournal Paper
    journal volume134
    journal issue4
    journal titleJournal of Water Resources Planning and Management
    identifier doi10.1061/(ASCE)0733-9496(2008)134:4(326)
    treeJournal of Water Resources Planning and Management:;2008:;Volume ( 134 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian