    Experimental Observation and Analysis of Inverse Transients for Pipeline Leak Detection

    Source: Journal of Water Resources Planning and Management:;2007:;Volume ( 133 ):;issue: 006
    Author:
    John P. Vítkovský
    ,
    Martin F. Lambert
    ,
    Angus R. Simpson
    ,
    James A. Liggett
    DOI: 10.1061/(ASCE)0733-9496(2007)133:6(519)
    Publisher: American Society of Civil Engineers
    Abstract: Fluid transients result in a substantial amount of data as pressure waves propagate throughout pipes. A new generation of leak detection and pipe roughness calibration techniques has arisen to exploit those data. Using the interactions of transient waves with leaks, the detection, location, and quantification of leakage using a combination of transient analysis and inverse mathematics is possible using inverse transient analysis (ITA). This paper presents further development of ITA and experimental observations for leak detection in a laboratory pipeline. The effects of data and model error on ITA results have been explored including strategies to minimize their effects using model error compensation techniques and ITA implementation approaches. The shape of the transient is important for successful application of ITA. A rapid input transient (which may be of small magnitude) contains maximum system response information, thus improving the uniqueness and quality of the ITA solution. The effect of using head measurements as boundary conditions for ITA has been shown to significantly reduce sensitivity, making both detection and quantification problematic. Model parsimony is used to limit the number of unknown leak candidates in ITA, thus reducing the minimization problem complexity. Experimental observations in a laboratory pipeline confirm the analysis and illustrate successful detection and quantification of both single and multiple leaks.
    • Download: (203.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Observation and Analysis of Inverse Transients for Pipeline Leak Detection

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/40109
    Collections
    • Journal of Water Resources Planning and Management

    Show full item record

    contributor authorJohn P. Vítkovský
    contributor authorMartin F. Lambert
    contributor authorAngus R. Simpson
    contributor authorJames A. Liggett
    date accessioned2017-05-08T21:08:18Z
    date available2017-05-08T21:08:18Z
    date copyrightNovember 2007
    date issued2007
    identifier other%28asce%290733-9496%282007%29133%3A6%28519%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/40109
    description abstractFluid transients result in a substantial amount of data as pressure waves propagate throughout pipes. A new generation of leak detection and pipe roughness calibration techniques has arisen to exploit those data. Using the interactions of transient waves with leaks, the detection, location, and quantification of leakage using a combination of transient analysis and inverse mathematics is possible using inverse transient analysis (ITA). This paper presents further development of ITA and experimental observations for leak detection in a laboratory pipeline. The effects of data and model error on ITA results have been explored including strategies to minimize their effects using model error compensation techniques and ITA implementation approaches. The shape of the transient is important for successful application of ITA. A rapid input transient (which may be of small magnitude) contains maximum system response information, thus improving the uniqueness and quality of the ITA solution. The effect of using head measurements as boundary conditions for ITA has been shown to significantly reduce sensitivity, making both detection and quantification problematic. Model parsimony is used to limit the number of unknown leak candidates in ITA, thus reducing the minimization problem complexity. Experimental observations in a laboratory pipeline confirm the analysis and illustrate successful detection and quantification of both single and multiple leaks.
    publisherAmerican Society of Civil Engineers
    titleExperimental Observation and Analysis of Inverse Transients for Pipeline Leak Detection
    typeJournal Paper
    journal volume133
    journal issue6
    journal titleJournal of Water Resources Planning and Management
    identifier doi10.1061/(ASCE)0733-9496(2007)133:6(519)
    treeJournal of Water Resources Planning and Management:;2007:;Volume ( 133 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian