YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Environmental Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Use of ORP for Monitoring and Control of Aerobic Sludge Digestion

    Source: Journal of Environmental Engineering:;1990:;Volume ( 116 ):;issue: 003
    Author:
    Craig C. Peddie
    ,
    Donald S. Mavinic
    ,
    Christopher J. Jenkins
    DOI: 10.1061/(ASCE)0733-9372(1990)116:3(461)
    Publisher: American Society of Civil Engineers
    Abstract: The oxidation‐reduction potential (ORP) was monitored within aerobic sludge digesters undergoing alternating aerated and nonaerated conditions. Observations were made on both bench‐scale and pilot‐scale reactors. Batch tests were also conducted on both reactors, involving a time series of chemical analyses, in conjunction with automated monitoring of reactor ORP and dissolved oxygen. The results indicated that a characteristic and reproducible ORP profile was associated with the cycled operation of the digesters. These real‐time ORP profiles had a number of distinctive features, directly related to changes in system chemistry and biological activity. The ranges of aerobic and anoxic respiration, as well as fermentation, were clearly defined by slope changes on the ORP profile. They also corresponded to the presence of the appropriate electron acceptors. The transition between the different ORP ranges was observed to be quite different during reaeration and deaeration. ORP was related to low levels of dissolved oxygen and nitrate. The data indicated that ORP could be used to measure very low oxygen concentrations. The reproducibility of the ORP profiles and sensitivity of the measured potential, to changes in biological or chemical activity, appears to make it an ideal parameter for automated monitoring and process control.
    • Download: (676.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Use of ORP for Monitoring and Control of Aerobic Sludge Digestion

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/38298
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorCraig C. Peddie
    contributor authorDonald S. Mavinic
    contributor authorChristopher J. Jenkins
    date accessioned2017-05-08T21:05:29Z
    date available2017-05-08T21:05:29Z
    date copyrightMay 1990
    date issued1990
    identifier other%28asce%290733-9372%281990%29116%3A3%28461%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/38298
    description abstractThe oxidation‐reduction potential (ORP) was monitored within aerobic sludge digesters undergoing alternating aerated and nonaerated conditions. Observations were made on both bench‐scale and pilot‐scale reactors. Batch tests were also conducted on both reactors, involving a time series of chemical analyses, in conjunction with automated monitoring of reactor ORP and dissolved oxygen. The results indicated that a characteristic and reproducible ORP profile was associated with the cycled operation of the digesters. These real‐time ORP profiles had a number of distinctive features, directly related to changes in system chemistry and biological activity. The ranges of aerobic and anoxic respiration, as well as fermentation, were clearly defined by slope changes on the ORP profile. They also corresponded to the presence of the appropriate electron acceptors. The transition between the different ORP ranges was observed to be quite different during reaeration and deaeration. ORP was related to low levels of dissolved oxygen and nitrate. The data indicated that ORP could be used to measure very low oxygen concentrations. The reproducibility of the ORP profiles and sensitivity of the measured potential, to changes in biological or chemical activity, appears to make it an ideal parameter for automated monitoring and process control.
    publisherAmerican Society of Civil Engineers
    titleUse of ORP for Monitoring and Control of Aerobic Sludge Digestion
    typeJournal Paper
    journal volume116
    journal issue3
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(1990)116:3(461)
    treeJournal of Environmental Engineering:;1990:;Volume ( 116 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace