    Earthquake Input Energy to Two Buildings Connected by Viscous Dampers

    Source: Journal of Structural Engineering:;2007:;Volume ( 133 ):;issue: 005
    Author:
    Izuru Takewaki
    DOI: 10.1061/(ASCE)0733-9445(2007)133:5(620)
    Publisher: American Society of Civil Engineers
    Abstract: A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and added viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. Fourier and inverse Fourier transformations enable one to transform the earthquake input energy in time domain to that in frequency domain. The earthquake input energy in frequency domain has an advantage that, while the input energy cannot be decomposed into the term for the structural parameters and that for the parameters of input ground motions in the conventional time-domain approach, it is possible in the proposed frequency-domain approach. It is demonstrated that the proposed energy transfer function is very useful for clearer understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It is concluded that the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity and location of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically.
    • Download: (913.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Earthquake Input Energy to Two Buildings Connected by Viscous Dampers

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/35026
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorIzuru Takewaki
    date accessioned2017-05-08T21:00:11Z
    date available2017-05-08T21:00:11Z
    date copyrightMay 2007
    date issued2007
    identifier other%28asce%290733-9445%282007%29133%3A5%28620%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/35026
    description abstractA frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and added viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. Fourier and inverse Fourier transformations enable one to transform the earthquake input energy in time domain to that in frequency domain. The earthquake input energy in frequency domain has an advantage that, while the input energy cannot be decomposed into the term for the structural parameters and that for the parameters of input ground motions in the conventional time-domain approach, it is possible in the proposed frequency-domain approach. It is demonstrated that the proposed energy transfer function is very useful for clearer understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It is concluded that the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity and location of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically.
    publisherAmerican Society of Civil Engineers
    titleEarthquake Input Energy to Two Buildings Connected by Viscous Dampers
    typeJournal Paper
    journal volume133
    journal issue5
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(2007)133:5(620)
    treeJournal of Structural Engineering:;2007:;Volume ( 133 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian