    Externally Prestressed Members: Evaluation of Second-Order Effects

    Source: Journal of Structural Engineering:;1999:;Volume ( 125 ):;issue: 010
    Author:
    M. Harajli
    ,
    N. Khairallah
    ,
    H. Nassif
    DOI: 10.1061/(ASCE)0733-9445(1999)125:10(1151)
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents the results of analytical investigation of the strength and structural behavior of concrete members prestressed with external tendons. The behavior at both the serviceability and ultimate limit states is evaluated. A nonlinear analysis model, based on the incremental deformation method, is developed to predict the entire response of concrete members originally designed with or strengthened by external prestressing. The proposed analysis reproduced experimental results of deflection and tendon stress responses with remarkable accuracy. A parametric study was undertaken to evaluate the behavior of concrete beams either designed using external prestressing or strengthened by it. The analytical results demonstrated that the second-order effect, associated with the progressive change in eccentricity of the tendons with increasing member deformation, is the main factor that distinguishes the behavior of external tendon from an internal unbonded tendon system. Because of this effect, undeviated external tendons mobilized lower nominal flexural resistance and inelastic deflections than did deviated tendons. When used for strengthening concrete flexural members, providing a moderate amount of external prestressing steel leads to significant deflection recovery, some reduction in the live load deflection, and a substantial increase in the yield load and ultimate flexural capacity of the members.
    • Download: (219.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Externally Prestressed Members: Evaluation of Second-Order Effects

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/33088
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorM. Harajli
    contributor authorN. Khairallah
    contributor authorH. Nassif
    date accessioned2017-05-08T20:57:16Z
    date available2017-05-08T20:57:16Z
    date copyrightOctober 1999
    date issued1999
    identifier other%28asce%290733-9445%281999%29125%3A10%281151%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/33088
    description abstractThis paper presents the results of analytical investigation of the strength and structural behavior of concrete members prestressed with external tendons. The behavior at both the serviceability and ultimate limit states is evaluated. A nonlinear analysis model, based on the incremental deformation method, is developed to predict the entire response of concrete members originally designed with or strengthened by external prestressing. The proposed analysis reproduced experimental results of deflection and tendon stress responses with remarkable accuracy. A parametric study was undertaken to evaluate the behavior of concrete beams either designed using external prestressing or strengthened by it. The analytical results demonstrated that the second-order effect, associated with the progressive change in eccentricity of the tendons with increasing member deformation, is the main factor that distinguishes the behavior of external tendon from an internal unbonded tendon system. Because of this effect, undeviated external tendons mobilized lower nominal flexural resistance and inelastic deflections than did deviated tendons. When used for strengthening concrete flexural members, providing a moderate amount of external prestressing steel leads to significant deflection recovery, some reduction in the live load deflection, and a substantial increase in the yield load and ultimate flexural capacity of the members.
    publisherAmerican Society of Civil Engineers
    titleExternally Prestressed Members: Evaluation of Second-Order Effects
    typeJournal Paper
    journal volume125
    journal issue10
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(1999)125:10(1151)
    treeJournal of Structural Engineering:;1999:;Volume ( 125 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian