Designing Structures for Snow LoadsSource: Journal of Structural Engineering:;1989:;Volume ( 115 ):;issue: 002Author:Ronald L. Sack
DOI: 10.1061/(ASCE)0733-9445(1989)115:2(303)Publisher: American Society of Civil Engineers
Abstract: Historical information, research results, and codes/standards provide the basis for a profile of snow load design practices in North America. Canada prescribes 30‐year mean recurrence interval (mri) ground snow using a Gumbel distribution, whereas the United States is adopting 50‐year mri ground snow modeled with a lognormal distribution. Ground‐to‐roof conversion factors are described with reference to the Canadian studies (1956–1967) and the nation‐wide measurements used in writing the 1982 standard for American National Standards Institute. Various field investigations revealed the effects on roof snow accumulations of roof exposure to wind and sun, roof geometry, roof cladding, and building thermal losses. We describe similarities in the three major model building codes, plus standards, in the United States, and the code of Canadian. Critical research needs on snow loads are also explained.
|
Collections
Show full item record
| contributor author | Ronald L. Sack | |
| date accessioned | 2017-05-08T20:53:12Z | |
| date available | 2017-05-08T20:53:12Z | |
| date copyright | February 1989 | |
| date issued | 1989 | |
| identifier other | %28asce%290733-9445%281989%29115%3A2%28303%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/30507 | |
| description abstract | Historical information, research results, and codes/standards provide the basis for a profile of snow load design practices in North America. Canada prescribes 30‐year mean recurrence interval (mri) ground snow using a Gumbel distribution, whereas the United States is adopting 50‐year mri ground snow modeled with a lognormal distribution. Ground‐to‐roof conversion factors are described with reference to the Canadian studies (1956–1967) and the nation‐wide measurements used in writing the 1982 standard for American National Standards Institute. Various field investigations revealed the effects on roof snow accumulations of roof exposure to wind and sun, roof geometry, roof cladding, and building thermal losses. We describe similarities in the three major model building codes, plus standards, in the United States, and the code of Canadian. Critical research needs on snow loads are also explained. | |
| publisher | American Society of Civil Engineers | |
| title | Designing Structures for Snow Loads | |
| type | Journal Paper | |
| journal volume | 115 | |
| journal issue | 2 | |
| journal title | Journal of Structural Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9445(1989)115:2(303) | |
| tree | Journal of Structural Engineering:;1989:;Volume ( 115 ):;issue: 002 | |
| contenttype | Fulltext |