    Z‐Section Girts Under Negative Loading

    Source: Journal of Structural Engineering:;1985:;Volume ( 111 ):;issue: 003
    Author:
    Dimos Polyzois
    ,
    Peter C. Birkemoe
    DOI: 10.1061/(ASCE)0733-9445(1985)111:3(528)
    Publisher: American Society of Civil Engineers
    Abstract: As part of a wall system in low‐rise industrial buildings, cold‐formed Z‐section girts are attached along one side to cold‐formed steel panels and are often supported along their span by sag rods. Thus, some degree otrestraint is present against the lateral and rotational displacement of these girts. The use of sag rods as a bracing device is often rejected in design on the assumption that the wall panels, once erected, provide adequate lateral restraint to the girts. However, if the wall system is under negative pressure, the Z‐sections are attached to the wall panels along the tension flange. In this case, the bracing contribution of the wall panels is also neglected in the design calculations. Results from a theoretical and experimental program showed that the omission of the restraint contribution of sag rods and steel panels leads to overconservative designs.
    • Download: (1.636Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Z‐Section Girts Under Negative Loading

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/29515
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorDimos Polyzois
    contributor authorPeter C. Birkemoe
    date accessioned2017-05-08T20:51:34Z
    date available2017-05-08T20:51:34Z
    date copyrightMarch 1985
    date issued1985
    identifier other%28asce%290733-9445%281985%29111%3A3%28528%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/29515
    description abstractAs part of a wall system in low‐rise industrial buildings, cold‐formed Z‐section girts are attached along one side to cold‐formed steel panels and are often supported along their span by sag rods. Thus, some degree otrestraint is present against the lateral and rotational displacement of these girts. The use of sag rods as a bracing device is often rejected in design on the assumption that the wall panels, once erected, provide adequate lateral restraint to the girts. However, if the wall system is under negative pressure, the Z‐sections are attached to the wall panels along the tension flange. In this case, the bracing contribution of the wall panels is also neglected in the design calculations. Results from a theoretical and experimental program showed that the omission of the restraint contribution of sag rods and steel panels leads to overconservative designs.
    publisherAmerican Society of Civil Engineers
    titleZ‐Section Girts Under Negative Loading
    typeJournal Paper
    journal volume111
    journal issue3
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)0733-9445(1985)111:3(528)
    treeJournal of Structural Engineering:;1985:;Volume ( 111 ):;issue: 003
    contenttypeFulltext