    Considerations for the Design of Intercepting Drainage for Collecting Water from Seep Areas

    Source: Journal of Irrigation and Drainage Engineering:;2006:;Volume ( 132 ):;issue: 006
    Author:
    Daniel Bucur
    ,
    Paul Savu
    DOI: 10.1061/(ASCE)0733-9437(2006)132:6(597)
    Publisher: American Society of Civil Engineers
    Abstract: Springs that appear at multiple sites on sloping lands and create problems of excess soil moisture and reduced crop yield require the implementation of a network of intercepting drains. The water removed by the intercepting drains also needs to be conducted to a collecting shaft or main drain, whereby it can be safely utilized or discharged back to a lower-lying position in the landscape. In this paper, we present a design method for establishing the position of the first row of interceptor drains and the number of successive rows of intercepting drains, as well as the distances between them. The first row of intercepting drains must be placed upstream of the upper limit of the wet area, through those points at which water-bearing material is found at
    • Download: (100.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Considerations for the Design of Intercepting Drainage for Collecting Water from Seep Areas

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/28492
    Collections
    • Journal of Irrigation and Drainage Engineering

    Show full item record

    contributor authorDaniel Bucur
    contributor authorPaul Savu
    date accessioned2017-05-08T20:49:49Z
    date available2017-05-08T20:49:49Z
    date copyrightDecember 2006
    date issued2006
    identifier other%28asce%290733-9437%282006%29132%3A6%28597%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/28492
    description abstractSprings that appear at multiple sites on sloping lands and create problems of excess soil moisture and reduced crop yield require the implementation of a network of intercepting drains. The water removed by the intercepting drains also needs to be conducted to a collecting shaft or main drain, whereby it can be safely utilized or discharged back to a lower-lying position in the landscape. In this paper, we present a design method for establishing the position of the first row of interceptor drains and the number of successive rows of intercepting drains, as well as the distances between them. The first row of intercepting drains must be placed upstream of the upper limit of the wet area, through those points at which water-bearing material is found at
    publisherAmerican Society of Civil Engineers
    titleConsiderations for the Design of Intercepting Drainage for Collecting Water from Seep Areas
    typeJournal Paper
    journal volume132
    journal issue6
    journal titleJournal of Irrigation and Drainage Engineering
    identifier doi10.1061/(ASCE)0733-9437(2006)132:6(597)
    treeJournal of Irrigation and Drainage Engineering:;2006:;Volume ( 132 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian