Effect of Gravel on Pumping Behavior of Compacted SoilSource: Journal of Geotechnical Engineering:;1996:;Volume ( 122 ):;issue: 010Author:Robert W. Day
DOI: 10.1061/(ASCE)0733-9410(1996)122:10(863)Publisher: American Society of Civil Engineers
Abstract: Pumping can occur when clay is compacted wet of optimum. Rather than densifying, the clayey soil squeezes out from underneath the compaction equipment. Adding gravel to the clayey soil creates a granular skeleton that increases the undrained shear strength. The results of this study show that even a partial gravel skeleton can prevent pumping of a clayey soil. Pumping occurred during the modified proctor compaction test when the undrained shear strength was less than 14 kPa (290 psf) and the initial tangent modulus was less than 1,600 kPa. To prevent pumping, the tested clayey soil (sand and montmorillonite mixture) had to contain at least 63% rounded gravel or 54% angular gravel. A lower percentage of angular gravel prevented pumping because it more effectively interlocked and created the necessary gravel skeleton at a lower density than the rounded gravel.
|
Collections
Show full item record
| contributor author | Robert W. Day | |
| date accessioned | 2017-05-08T20:37:51Z | |
| date available | 2017-05-08T20:37:51Z | |
| date copyright | October 1996 | |
| date issued | 1996 | |
| identifier other | %28asce%290733-9410%281996%29122%3A10%28863%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/21746 | |
| description abstract | Pumping can occur when clay is compacted wet of optimum. Rather than densifying, the clayey soil squeezes out from underneath the compaction equipment. Adding gravel to the clayey soil creates a granular skeleton that increases the undrained shear strength. The results of this study show that even a partial gravel skeleton can prevent pumping of a clayey soil. Pumping occurred during the modified proctor compaction test when the undrained shear strength was less than 14 kPa (290 psf) and the initial tangent modulus was less than 1,600 kPa. To prevent pumping, the tested clayey soil (sand and montmorillonite mixture) had to contain at least 63% rounded gravel or 54% angular gravel. A lower percentage of angular gravel prevented pumping because it more effectively interlocked and created the necessary gravel skeleton at a lower density than the rounded gravel. | |
| publisher | American Society of Civil Engineers | |
| title | Effect of Gravel on Pumping Behavior of Compacted Soil | |
| type | Journal Paper | |
| journal volume | 122 | |
| journal issue | 10 | |
| journal title | Journal of Geotechnical Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9410(1996)122:10(863) | |
| tree | Journal of Geotechnical Engineering:;1996:;Volume ( 122 ):;issue: 010 | |
| contenttype | Fulltext |