    Correlations Between Simple Field Test and Relative Density-Test Values

    Source: Journal of Geotechnical Engineering:;1996:;Volume ( 122 ):;issue: 010
    Author:
    Danny K. McCook
    DOI: 10.1061/(ASCE)0733-9410(1996)122:10(860)
    Publisher: American Society of Civil Engineers
    Abstract: Correlations developed between a simple field test, a 1 point standard Proctor test on air-dry sand, and relative density-test values are presented for 29 filter sands studied. The correlations allow prediction of 70 and 50% relative density values from the field 1 point compaction test value. The field 1 point standard Proctor dry-density value on air-dry sand was greater than the 50% relative density value for all 29 sands tested.
    • Download: (294.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Correlations Between Simple Field Test and Relative Density-Test Values

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/21745
    Collections
    • Journal of Geotechnical Engineering

    Show full item record

    contributor authorDanny K. McCook
    date accessioned2017-05-08T20:37:51Z
    date available2017-05-08T20:37:51Z
    date copyrightOctober 1996
    date issued1996
    identifier other%28asce%290733-9410%281996%29122%3A10%28860%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/21745
    description abstractCorrelations developed between a simple field test, a 1 point standard Proctor test on air-dry sand, and relative density-test values are presented for 29 filter sands studied. The correlations allow prediction of 70 and 50% relative density values from the field 1 point compaction test value. The field 1 point standard Proctor dry-density value on air-dry sand was greater than the 50% relative density value for all 29 sands tested.
    publisherAmerican Society of Civil Engineers
    titleCorrelations Between Simple Field Test and Relative Density-Test Values
    typeJournal Paper
    journal volume122
    journal issue10
    journal titleJournal of Geotechnical Engineering
    identifier doi10.1061/(ASCE)0733-9410(1996)122:10(860)
    treeJournal of Geotechnical Engineering:;1996:;Volume ( 122 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian