    Long-Term Pullout Behavior of Polymeric Geogrids

    Source: Journal of Geotechnical Engineering:;1995:;Volume ( 121 ):;issue: 010
    Author:
    Ragui F. Wilson-Fahmy
    ,
    Robert M. Koerner
    ,
    W. Andrew Harpur
    DOI: 10.1061/(ASCE)0733-9410(1995)121:10(723)
    Publisher: American Society of Civil Engineers
    Abstract: Polymeric geogrids are widely used in various geotechnical-, transportation-, and environmental-related applications. Among the major uses of geogrids are reinforced soil walls, steep slopes, and landfill expansions. Current design practices are based on limit equilibrium techniques in which the geogrid is assumed to resist failure by mobilizing sufficient tensile resistance within the potential failure zone. The geogrid must also extend a sufficient distance beyond the potential failure surface to ensure sufficient anchorage resistance and thus resistance to pullout failure. This paper focuses on the anchorage behavior of geogrids under both short-term and sustained (1,000 h) conditions. An experimental investigation is conducted using five different geogrids in granular soil tested under two different normal stresses of 28 and 69 kPa. The geogrid length in all tests is taken equal to 0.9 m, which is often the requirement for the minimum anchorage length beyond the failure plane. Results of the tests are presented in terms of load-displacement curves and time-displacement curves. The results indicate that for practical purposes, the pullout strength after 1,000-h sustained loading can be assumed to be equal to the short-term pullout strength provided sufficient length of the geogrid is available to mobilize its full strength and/or the structural integrity of the geogrid is maintained during pullout over its length.
    • Download: (700.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Long-Term Pullout Behavior of Polymeric Geogrids

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/21547
    Collections
    • Journal of Geotechnical Engineering

    Show full item record

    contributor authorRagui F. Wilson-Fahmy
    contributor authorRobert M. Koerner
    contributor authorW. Andrew Harpur
    date accessioned2017-05-08T20:37:28Z
    date available2017-05-08T20:37:28Z
    date copyrightOctober 1995
    date issued1995
    identifier other%28asce%290733-9410%281995%29121%3A10%28723%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/21547
    description abstractPolymeric geogrids are widely used in various geotechnical-, transportation-, and environmental-related applications. Among the major uses of geogrids are reinforced soil walls, steep slopes, and landfill expansions. Current design practices are based on limit equilibrium techniques in which the geogrid is assumed to resist failure by mobilizing sufficient tensile resistance within the potential failure zone. The geogrid must also extend a sufficient distance beyond the potential failure surface to ensure sufficient anchorage resistance and thus resistance to pullout failure. This paper focuses on the anchorage behavior of geogrids under both short-term and sustained (1,000 h) conditions. An experimental investigation is conducted using five different geogrids in granular soil tested under two different normal stresses of 28 and 69 kPa. The geogrid length in all tests is taken equal to 0.9 m, which is often the requirement for the minimum anchorage length beyond the failure plane. Results of the tests are presented in terms of load-displacement curves and time-displacement curves. The results indicate that for practical purposes, the pullout strength after 1,000-h sustained loading can be assumed to be equal to the short-term pullout strength provided sufficient length of the geogrid is available to mobilize its full strength and/or the structural integrity of the geogrid is maintained during pullout over its length.
    publisherAmerican Society of Civil Engineers
    titleLong-Term Pullout Behavior of Polymeric Geogrids
    typeJournal Paper
    journal volume121
    journal issue10
    journal titleJournal of Geotechnical Engineering
    identifier doi10.1061/(ASCE)0733-9410(1995)121:10(723)
    treeJournal of Geotechnical Engineering:;1995:;Volume ( 121 ):;issue: 010
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace