Variability in Compaction ControlSource: Journal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 007Author:Iraj Noorany
DOI: 10.1061/(ASCE)0733-9410(1990)116:7(1132)Publisher: American Society of Civil Engineers
Abstract: A field study was made for evaluation of variability in degree of compaction of structural fills. Multiple runs of field‐density tests were performed at three sites by nine geotechnical engineering firms in San Diego, California. The tests were run after the geotechnical engineer had tested and approved each site as having met the 90% relative compaction requirement. All tests at each site were performed at the same time and at the same elevation in close proximity to each other. A statistical analysis of the results indicated a significant scatter in percent compaction data: The range of variations, expressed as a percentage of the mean value, were about 17% for a uniform silty sand fill, 15% for a silty clay fill, and 26% for a gravelly to cobbly sand fill. This amount of variability in relative compaction is greater than that generally found in embankment dams. This is partly because the standards of practice for mass grading of structural fills are less rigorous than for dams, and partly because of inadequate or imperfect fill‐control procedures.
|
Collections
Show full item record
| contributor author | Iraj Noorany | |
| date accessioned | 2017-05-08T20:35:45Z | |
| date available | 2017-05-08T20:35:45Z | |
| date copyright | July 1990 | |
| date issued | 1990 | |
| identifier other | %28asce%290733-9410%281990%29116%3A7%281132%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/20661 | |
| description abstract | A field study was made for evaluation of variability in degree of compaction of structural fills. Multiple runs of field‐density tests were performed at three sites by nine geotechnical engineering firms in San Diego, California. The tests were run after the geotechnical engineer had tested and approved each site as having met the 90% relative compaction requirement. All tests at each site were performed at the same time and at the same elevation in close proximity to each other. A statistical analysis of the results indicated a significant scatter in percent compaction data: The range of variations, expressed as a percentage of the mean value, were about 17% for a uniform silty sand fill, 15% for a silty clay fill, and 26% for a gravelly to cobbly sand fill. This amount of variability in relative compaction is greater than that generally found in embankment dams. This is partly because the standards of practice for mass grading of structural fills are less rigorous than for dams, and partly because of inadequate or imperfect fill‐control procedures. | |
| publisher | American Society of Civil Engineers | |
| title | Variability in Compaction Control | |
| type | Journal Paper | |
| journal volume | 116 | |
| journal issue | 7 | |
| journal title | Journal of Geotechnical Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9410(1990)116:7(1132) | |
| tree | Journal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 007 | |
| contenttype | Fulltext |