    Archive

    Evaluation of In Situ Permeability Testing Methods

    Source: Journal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 002
    Author:
    Neal Fernuik
    ,
    Moir Haug
    DOI: 10.1061/(ASCE)0733-9410(1990)116:2(297)
    Publisher: American Society of Civil Engineers
    Abstract: A testing program was established to determine the accuracy and efficiency of in situ permeability testing equipment. The sealed single‐ring infiltrometer, sealed double‐ring infiltrometer, and air‐entry permeameter were evaluated in this study. The theoretical basis for each of these tests was examined and their testing procedures outlined. The accuracy and ease of use of these devices was demonstrated by full‐scale tests under controlled field and laboratory conditions. The field permeability tests were conducted on a residual soil‐liner test pad installed at a site near Jamestown, California. The laboratory permeability tests were conducted on a prototype liner composed of uniform Ottawa sand and sodium bentonite. This material was mixed, moisture‐conditioned, and compacted into reinforced wooden frames. The in situ permeability test results were verified with low‐gradient, back‐pressure saturated triaxial permeameter tests conducted on undisturbed 101.4 mm (4 in.) cored and remolded samples. This evaluation shows that good agreement can be obtained between in situ field and laboratory triaxial permeability tests results. In addition, changes in hydraulic conductivity of hydrating sand‐bentonite with time observed in the in situ tests, closely approximated the results obtained in the triaxial permeability tests. This evaluation also demonstrated that considerable care was required setting up and conducting in situ permeability tests, in order to obtain reliable results.
    • Download: (866.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Evaluation of In Situ Permeability Testing Methods

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/20596
    Collections
    • Journal of Geotechnical Engineering

    Show full item record

    contributor authorNeal Fernuik
    contributor authorMoir Haug
    date accessioned2017-05-08T20:35:37Z
    date available2017-05-08T20:35:37Z
    date copyrightFebruary 1990
    date issued1990
    identifier other%28asce%290733-9410%281990%29116%3A2%28297%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/20596
    description abstractA testing program was established to determine the accuracy and efficiency of in situ permeability testing equipment. The sealed single‐ring infiltrometer, sealed double‐ring infiltrometer, and air‐entry permeameter were evaluated in this study. The theoretical basis for each of these tests was examined and their testing procedures outlined. The accuracy and ease of use of these devices was demonstrated by full‐scale tests under controlled field and laboratory conditions. The field permeability tests were conducted on a residual soil‐liner test pad installed at a site near Jamestown, California. The laboratory permeability tests were conducted on a prototype liner composed of uniform Ottawa sand and sodium bentonite. This material was mixed, moisture‐conditioned, and compacted into reinforced wooden frames. The in situ permeability test results were verified with low‐gradient, back‐pressure saturated triaxial permeameter tests conducted on undisturbed 101.4 mm (4 in.) cored and remolded samples. This evaluation shows that good agreement can be obtained between in situ field and laboratory triaxial permeability tests results. In addition, changes in hydraulic conductivity of hydrating sand‐bentonite with time observed in the in situ tests, closely approximated the results obtained in the triaxial permeability tests. This evaluation also demonstrated that considerable care was required setting up and conducting in situ permeability tests, in order to obtain reliable results.
    publisherAmerican Society of Civil Engineers
    titleEvaluation of In Situ Permeability Testing Methods
    typeJournal Paper
    journal volume116
    journal issue2
    journal titleJournal of Geotechnical Engineering
    identifier doi10.1061/(ASCE)0733-9410(1990)116:2(297)
    treeJournal of Geotechnical Engineering:;1990:;Volume ( 116 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian