Show simple item record

contributor authorT. A. Jur
date accessioned2017-05-09T01:38:12Z
date available2017-05-09T01:38:12Z
date copyrightJuly, 1974
date issued1974
identifier issn0094-4289
identifier otherJEMTA8-26837#195_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/164808
description abstractA diameter gage is described which has been used to obtain true stress-true strain data at elevated temperatures. The device is capable of continuously and automatically measuring diameter of a tensile specimen to a true strain as high as 0.90–0.95. Data are presented which demonstrate the ability of the gage to identify conditions of non-uniform deformation behavior.
publisherThe American Society of Mechanical Engineers (ASME)
titleDiameter Gage for Use at Elevated Temperatures and Intermediate Tensile Strain Rates
typeJournal Paper
journal volume96
journal issue3
journal titleJournal of Engineering Materials and Technology
identifier doi10.1115/1.3443210
journal fristpage195
journal lastpage200
identifier eissn1528-8889
keywordsTemperature
keywordsGages
keywordsStress AND Deformation
treeJournal of Engineering Materials and Technology:;1974:;volume( 096 ):;issue: 003