Show simple item record

contributor authorTadeusz M. Drzewiecki
date accessioned2017-05-09T01:37:53Z
date available2017-05-09T01:37:53Z
date copyrightSeptember, 1974
date issued1974
identifier issn0022-0434
identifier otherJDSMAA-26016#358_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/164638
description abstractA possible fluidic load cell design consists of three parts: a structural member that deforms linearly with load, a fluidic strain gage having fluidic resistance that changes with deformation, and a three-stage laminar proportional amplifier-gain block that amplifies the change in strain gage through-flow to useful levels. This Technical Brief presents design relations for the first two parts of such a system. Two compressive load cells were built, incorporating different fabrication techniques and deformation-sensing methods. The loading range of these cells is about 0 to 20 kN (0 to 2 tons) with a dynamic range greater than 100 and a typical full-scale output pressure of 30 pascals (4 × 10−3 psi). Possible applications for fluidic load cells include force measurements in highly incendiary or radiative environments and/or when other fluid control circuitry is used.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Fluidic Load Cell
typeJournal Paper
journal volume96
journal issue3
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.3426815
journal fristpage358
journal lastpage360
identifier eissn1528-9028
keywordsStress
keywordsDeformation
keywordsDesign
keywordsStrain gages
keywordsForce measurement
keywordsFluids
keywordsManufacturing
keywordsElectrical resistance
keywordsKnudsen number
keywordsPressure AND Flow (Dynamics)
treeJournal of Dynamic Systems, Measurement, and Control:;1974:;volume( 096 ):;issue: 003