| contributor author | R. P. Benedict | |
| contributor author | R. D. Schulte | |
| date accessioned | 2017-05-09T01:36:32Z | |
| date available | 2017-05-09T01:36:32Z | |
| date copyright | September, 1973 | |
| date issued | 1973 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-26849#337_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/163867 | |
| description abstract | The concept of critical static pressure ratio across a fluid meter is first discussed. Various formulations for critical pressure ratios are then developed and solutions are tabulated for convenience. Conclusions, based on graphical and numerical studies, are drawn as to which critical pressure ratios apply in the various supercritical formulations. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Note on the Critical Pressure Ratio Across a Fluid Meter | |
| type | Journal Paper | |
| journal volume | 95 | |
| journal issue | 3 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3447035 | |
| journal fristpage | 337 | |
| journal lastpage | 341 | |
| identifier eissn | 1528-901X | |
| keywords | Pressure AND Flowmeters | |
| tree | Journal of Fluids Engineering:;1973:;volume( 095 ):;issue: 003 | |
| contenttype | Fulltext | |