    Archive

    Aerodynamic Effects Due to Configuration of X-Wire Anemometers

    Source: Journal of Applied Mechanics:;1973:;volume( 040 ):;issue: 003::page 661
    Author:
    A. Strohl
    ,
    G. Comte-Bellot
    DOI: 10.1115/1.3423069
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Two separate “reference” wires were arranged to act as an X-wire. First, the effects of the orientation of one of the wires with respect to the other, and of both wires with respect to the mean flow, were investigated. Then, components of typical hot-wire probes (stem, prongs, . . .) were being advanced toward the reference wires. The analysis of the response of the reference wires during the advancement uncovered (a) a perturbation induced on the RMS value v′ of the transverse component of the velocity fluctuation and on the Reynolds stress uv , (b) changes of the wire sensitivities, and therefore also (c) errors affecting the v′ and uv measurements performed with typical probes.
    keyword(s): Wire , Probes , Stress , Errors , Flow (Dynamics) AND Measurement ,
    • Download: (536.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Aerodynamic Effects Due to Configuration of X-Wire Anemometers

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/163410
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorA. Strohl
    contributor authorG. Comte-Bellot
    date accessioned2017-05-09T01:35:48Z
    date available2017-05-09T01:35:48Z
    date copyrightSeptember, 1973
    date issued1973
    identifier issn0021-8936
    identifier otherJAMCAV-25989#661_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/163410
    description abstractTwo separate “reference” wires were arranged to act as an X-wire. First, the effects of the orientation of one of the wires with respect to the other, and of both wires with respect to the mean flow, were investigated. Then, components of typical hot-wire probes (stem, prongs, . . .) were being advanced toward the reference wires. The analysis of the response of the reference wires during the advancement uncovered (a) a perturbation induced on the RMS value v′ of the transverse component of the velocity fluctuation and on the Reynolds stress uv , (b) changes of the wire sensitivities, and therefore also (c) errors affecting the v′ and uv measurements performed with typical probes.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAerodynamic Effects Due to Configuration of X-Wire Anemometers
    typeJournal Paper
    journal volume40
    journal issue3
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.3423069
    journal fristpage661
    journal lastpage667
    identifier eissn1528-9036
    keywordsWire
    keywordsProbes
    keywordsStress
    keywordsErrors
    keywordsFlow (Dynamics) AND Measurement
    treeJournal of Applied Mechanics:;1973:;volume( 040 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian