    Comparison of Flow Fields in a Centrifugal Pump Among Different Tracer Particles by Particle Image Velocimetry

    Source: Journal of Fluids Engineering:;2016:;volume( 138 ):;issue: 006::page 61105
    Author:
    Li, Yalin
    ,
    Yuan, Shouqi
    ,
    Wang, Xikun
    ,
    Keat Tan, Soon
    ,
    Mao, Jieyun
    DOI: 10.1115/1.4032562
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents an experimental investigation of the flow fields in a centrifugal pump by particle image velocimetry (PIV) technique with two different tracer particles, all designed for the same operating point. In order to systematically analyze the tracking characteristics of tracer particles once used in centrifugal pump by Basset–Boussinesq–Oseen (BBO) equation, aluminum powder (AP, with high density ratio and small diameter) and hollow glass spheres (HGS, with neutral density and large diameter) were selected. The velocity fields obtained for AP and HGS were presented and compared, in order to enhance the understanding of their tracking properties in rotating impeller. The results show that AP and HGS give nearly the same phaseaveraged velocity fields except at two small regions. BBO extended equation by the phase average theory in a centrifugal pump was applied to explain the first difference, namely, why the velocity of HGS is higher than that of AP in the lowspeed zone. In addition, the mean vorticity distributions for AP and HGS show high strength velocity micelles with different directions of development and dissemination, which causes the second difference in energy exchange. As a consequence, HGS tends to conglomerate closer to the pressure side (PS) near the impeller outlet than AP
    • Download: (5.452Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Comparison of Flow Fields in a Centrifugal Pump Among Different Tracer Particles by Particle Image Velocimetry

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/161386
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorLi, Yalin
    contributor authorYuan, Shouqi
    contributor authorWang, Xikun
    contributor authorKeat Tan, Soon
    contributor authorMao, Jieyun
    date accessioned2017-05-09T01:29:39Z
    date available2017-05-09T01:29:39Z
    date issued2016
    identifier issn0098-2202
    identifier otherfe_138_06_061105.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/161386
    description abstractThis paper presents an experimental investigation of the flow fields in a centrifugal pump by particle image velocimetry (PIV) technique with two different tracer particles, all designed for the same operating point. In order to systematically analyze the tracking characteristics of tracer particles once used in centrifugal pump by Basset–Boussinesq–Oseen (BBO) equation, aluminum powder (AP, with high density ratio and small diameter) and hollow glass spheres (HGS, with neutral density and large diameter) were selected. The velocity fields obtained for AP and HGS were presented and compared, in order to enhance the understanding of their tracking properties in rotating impeller. The results show that AP and HGS give nearly the same phaseaveraged velocity fields except at two small regions. BBO extended equation by the phase average theory in a centrifugal pump was applied to explain the first difference, namely, why the velocity of HGS is higher than that of AP in the lowspeed zone. In addition, the mean vorticity distributions for AP and HGS show high strength velocity micelles with different directions of development and dissemination, which causes the second difference in energy exchange. As a consequence, HGS tends to conglomerate closer to the pressure side (PS) near the impeller outlet than AP
    publisherThe American Society of Mechanical Engineers (ASME)
    titleComparison of Flow Fields in a Centrifugal Pump Among Different Tracer Particles by Particle Image Velocimetry
    typeJournal Paper
    journal volume138
    journal issue6
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.4032562
    journal fristpage61105
    journal lastpage61105
    identifier eissn1528-901X
    treeJournal of Fluids Engineering:;2016:;volume( 138 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian